background image

4.3 - Transmitter to be used for programming 

procedures

• 

Procedures that can only be completed with a Nice “ERA P” or “ERA W” 

transmitter having the PRG and ESC keys, or with transmitters equipped 

with a STOP key.

• 

All the programming procedures must be completed by selecting a single 

channel on the transmitter.

• The programming procedure must be performed exclusively with a transmitter 

memorised in “Mode I” (see procedure 

B.1 - A.1 - D.1

).

• If the transmitter used for programming controls multiple automation units, you 

must select the “unit” corresponding to the automation you are programming before 
sending a command during a procedure.

4.3.1 - Report messages sent by the motor

The motor repeats the report message on the status of the installation by performing 
some brief movements when a movement is commanded. To understand the signifi-
cance of these movements read 

Table A

.

TABLE A

 – Movement signals

No. of MOVEMENTS

Meaning

0 movements (START & STOP)

= 2 limit switches programmed

1 movement (START & STOP)

= 1 limit switch programmed

2 movements (START & STOP)

= no limit switch programmed

4.4 - Positions in which the roller shutter stops 

automatically

The electronic system that controls the roller shutter’s movement at all times can au-
tomatically stop the movement when the roller shutter reaches a certain position pro-
grammed by the installer. The programmable positions are (

fig. 4

):

– position “

0

” = 

UPPER

 (fully wound roller shutter);

– position “

1

” = 

LOWER

 (fully unwound roller shutter);

– position “

H

” = 

INTERMEDIATE

 (partially open roller shutter).

1

0

H

4

With box

 

(the Up limit switch position will be determined by the point 
where the roller shutter strikes the box).

When the limit switches are not programmed yet, the roller shutter can be moved only 
in the “hold-to-run” mode, i.e. keeping the control key pressed for the desired dura-
tion of the manoeuvre; the movement stops as soon as the user releases the key. 
However, after programming the limit switches, briefly pressing the appropriate key 
will start the roller shutter and it will stop moving automatically as soon as the roller 
shutter reaches the required position.

To adjust the distances “

0

” and “

1

” various procedures are possible; to choose the 

appropriate one, take into account the supporting structure of your roller shutter (see 
the summary in the table).

WARNING! – If you want to again adjust again the height of the limit switches 

adjusted previously, consider the following:
–  If you would like to adjust them with an alternative procedure different 

from the one used previously, you must FIRST delete the heights by fol-

lowing procedure B.11, A.10 or C.4.

–  If you wish to adjust the same procedure used previously, you need not 

delete them.

The programming of the limit switches simultaneously combines the two directions 
of rotation of the motor to the respective shutter raising key (

) and shutter lowering 

key (

) of the control device (initially, when the limit switches are not programmed 

yet, the combination is random and it can happen that when pressing the 

 key, the 

roller shutter moves down instead of up, or vice versa).

4.5 - General warnings

• The limit switch must be adjusted after installing the motor in the roller shutter and 

connecting it to the power supply.

• Comply strictly with the time limits indicated in the procedures: after releasing a key, 

you have 60 seconds to press the next key indicated in the procedure; otherwise, 
when the time is up, the motor will perform 6 movements to communicate cancel-
lation of the procedure in progress.

• During programming the motor performs a certain number of 

brief movements 

as a “response” to the command sent by the installer. Count these movements 
regardless of their direction. The movements are indicated in the procedures with a 
number followed by the symbol 

 .

4.6 - Important warnings for memorising the radio 

transmitters

• To select transmitter compatible with the motor’s receiver, refer to the “Nice 

Screen” catalogue, which is also available on www.niceforyou.com.

• When the motor’s memory does not contain any transmitter, to memorise the 

FIRST transmitter

, perform the “Communication mode configuration procedure 

(ONE-WAY or TWO-WAY)” and subsequently use only one of the following pro-
cedures: 

B.1

 (motor configured as ONE-WAY); 

A.1

 (motor configured as TWO-

WAY); 

C.1

 (motor configured as ONE-WAY and 

OLD

 generation transmitter lack-

ing the 

PRG

 and 

ESC

 keys). If instead one or more transmitters have already been 

memorised, to memorise 

SUPPLEMENTARY transmitters

 use one of following 

procedures only: 

B.7

 (motor configured as ONE-WAY); 

A.8

 (motor configured as 

TWO-WAY); 

C.2

 (motor configured as ONE-WAY and 

OLD

 generation transmitter 

lacking the 

PRG

 and 

ESC

 keys).

4.6.1 - Two procedures to memorise the keys of a transmitter

There are two categories of transmitter memorisation procedures:

A - Procedures which memorise the buttons in “Mode I” 

(“Standard mode”)

 

They are procedures B.1 - B.7.1 (motor configured as ONE-WAY); A.1 - 

A.7 (motor configured as TWO-WAY); C.1 - C.2.1 (motor configured as 

ONE-WAY and OLD generation transmitter lacking the PRG and ESC 

keys). 

These allow you to memorise all buttons 

at the same time

, so that 

each button corresponds to a basic motor command in a standard fashion.

B - Procedures which memorise the buttons in “Mode II” 

(“Custom mode”, only applicable when the motor is con-

figured for ONE-WAY communications

 

These are procedures B.7.2, A.7 and C.2.2.

 These allow you to memorise 

individual buttons

 and map them to any of the commands given in the mo-

tor’s “list of commands” (this list is given in each procedure). The button and the 
command are selected by the installer, as required by the installation.

4.6.2 - Number of transmitters that can be memorised (only 

applicable when the motor is configured for ONE-WAY 

communications)

You can memorise 

30 transmitters

, if these are all memorised in “Mode I”, or you 

can memorise 

30 single commands (keys)

 if they are all memorised in “Mode II”. 

The two modes can coexist up to a maximum limit of 30 memorised units.

4.6.3 - Number of transmitters that can be memorised (only 

applicable when the motor is configured for TWO-WAY 

communications)

You can memorise 

30 transmitters

.

5

 – English

Содержание NX SOL MA 1014 SH BD

Страница 1: ...Nice EN Instructions and warnings for installation and use Tubular Motor NX SOL MA 615 SH BD NX SOL MA 1014 SH BD NX SOL MA 2010 SH BD ...

Страница 2: ...his happen stop installation immediately and contact Customer Service The manufacturer assumes no liability for damage to property items or persons resulting from non compliance with the assembly instructions In such cases the warranty for material defects is excluded The weighted sound pressure level of the emission A is lower than 70 dB A Cleaning and maintenance to be carried out by the user mu...

Страница 3: ...n stop it at the upper limit switch the lower limit switch or various intermediate positions up to 30 if the mo tor is configured for operating in ONE WAY mode or up to 6 if it is configured for operating in TWO WAY mode is equipped with a thermal protection device which in case of extended use pro tect the motor against excessive overheating by limiting the motor speed to the min imum speed in th...

Страница 4: ...transmitter paired with the motor ONE WAY or TWO WAY If the motor is new and has no remote control memorised when it starts up it enters the ONE WAY mode and thus can accept all one way transmitters If within 15 seconds of start up no one way transmitter is paired with it the motor will make a brief movement to signal that it has entered TWO WAY mode and will therefore only be able to communicate ...

Страница 5: ...d M 10 mm e c a 3 i b f Support for fixing the motor head g Cap for fixing the roller to the bracket not included 1 1 2 h Removing the connector if necessary English 4 ...

Страница 6: ...and it can happen that when pressing the s key the roller shutter moves down instead of up or vice versa 4 5 General warnings The limit switch must be adjusted after installing the motor in the roller shutter and connecting it to the power supply Comply strictly with the time limits indicated in the procedures after releasing a key you have 60 seconds to press the next key indicated in the procedu...

Страница 7: ...0 motor configured for TWO WAY communication or C 4 motor configured for ONE WAY communication and OLD generation transmitter lacking the PRG and ESC buttons and then switch the motor off and on again WARNING if the motor is new and does not have any remote control memorised at the start up run one of the memorisation procedures for the first transmitter described at points B 1 motor configured fo...

Страница 8: ...ccess it by completing the Memorising the FIRST TRANSMITTER A 1 procedure To change the motor s configuration from ONE WAY to TWO WAY and inversely it is necessary to perform the TO TAL deletion of the memory procedure B 11 motor configured for ONE WAY communication A 10 motor configured for TWO WAY communication or C 4 motor configured for ONE WAY communication and OLD generation transmitter lack...

Страница 9: ...shutter at the Up limit 0 For a period of 5 minutes the locked out motors will not respond to commands A 2 2 To reactivate temporarily locked out motors You can reactivate the motors in two ways option A 1 end After 5 minutes the locked out motors are automatically reactivated by the system Wait for 5 minutes the system will then move the roller shutter to the mid position option B 1 end During th...

Страница 10: ... button 1 time count 2 movements Hold down the but ton and release it after 5 seconds count 2 movements Hold down the button or and wait 3 4 5 end 0 Finely adjust ing the posi tion of limit switch 0 0 5 sec 3 release the button as soon as the roller shut ter reaches position 0 UP limit switch Press the buttons until you reach the desired position Hold down the button and release it after 5 seconds...

Страница 11: ...s with the box UP limit switch position 0 release the button Hold down the button or and wait 2 3 4 5 1 x 1 PRG 2 5 sec 2 release the button as soon as the roller shutter reaches position 1 DOWN limit switch Press and release the button 1 time count 2 movements Hold down the but ton and release it after 5 seconds count 2 movements 5 6 end Finely adjust ing the posi tion of limit switch 1 1 5 sec 3...

Страница 12: ...figured to operate in ONE WAY mode or up to 6 H positions if the motor is configured to operate in TWO WAY mode in any desired position provided that they are within the space delimited by the two limit switches These positions can only be programmed after the limit switch positions Repeat this procedure for each position you wish to memorise The first H position must be programmed using the butto...

Страница 13: ...n deactivated Press and release the button the number of times indicated in the option you have chosen 4 5 end 10 sec 1 2 3 4 5 5 sec 3 After about 10 seconds the motor performs a number of movements equal to the number of pulses entered Hold down the button and release it after 5 sec onds count 3 movements A A 9 Behaviour of the motor in the presence of an obstacle BiDi NOTES AND WARNINGS This pr...

Страница 14: ...tc Caution This deletion should only be performed if you wish re program the distances using a procedure different from the one used previously e g you have used manual distance pro gramming A 3 and would now like to use the semi automatic procedure A 5 Warning Once the procedure relative to the chosen option A B C or D has been completed perform the dissociation procedure for the two way remote c...

Страница 15: ...er s movement including alignments and other effects that are useful especially when multiple roller shutters are installed close to one another with different sizes and rollers of different diameters or for making the shutter s movement more silent The Total manoeuvre duration procedure A 12 and the Roller shutter cruising speed procedure A 11 functions are interdependent the last function set de...

Страница 16: ...t 7 seconds the motor performs a number of movements equal to the number of pulses entered Hold down the button and release it after 5 seconds count 3 movements A A 13 Adjusting the Soft Start Soft Stop movement BiDi NOTES AND WARNINGS This procedure can be used to activate adjust or deactivate the Soft Start Soft Stop movement The following options are available function DEACTIVATED 1 2 turn 3 4 ...

Страница 17: ...ng the PRG and ESC keys To change the motor s configuration from ONE WAY to TWO WAY and inversely it is necessary to perform the TOTAL deletion of the memory procedure B 11 motor configured for ONE WAY communication A 10 motor configured for TWO WAY communication or C 4 motor configured for ONE WAY communication and OLD generation transmitter lacking the PRG and ESC buttons and then switch the mot...

Страница 18: ... down the button or and wait 3 4 5 end 0 Regolare con precisione la quota del fine corsa 0 0 5 sec 3 release the button as soon as the roller shutter reaches position 0 UP limit switch Press the buttons until you reach the desired position Hold down the button and release it after 5 seconds count 3 movements B B 2 Locking and unlocking the motor s memory MONO NOTES AND WARNINGS Locking the motor s...

Страница 19: ...king devices Programme the UP limit switch 0 FIRST The down limit switch 1 is NOT memorised if it is within 120 with respect to the UP limit switch 0 If the limit switches have not been programmed yet the roller shutter s direction of movement might not match the pressed button After programming the limit switches the s key will command the Up manoeuvre and the t switch will command the Down manoe...

Страница 20: ...nt will be limited when the roller shutter impacts against the mechanical lock box in the Upper limit switch 0 With each impact the height of this limit switch will be automatically updated by the Automatic limit switch update function paragraph 5 4 Conversely the Down movement will be limited by the Lower limit switch 1 limit switch set by the installer at a desired point 1 2 continues Command an...

Страница 21: ...tons release them after 5 sec onds count 2 movements 4 5 6 Precisely ad justing the H posi tion H 5 sec 3 Select one of the following potions and execute it option A to memorise the FIRST H position option B to memorise a SUP PLEMENTARY H position Press the buttons until you reach the desired position Hold down the but ton and release it after 5 sec onds count 3 movements option A 6 end option B 6...

Страница 22: ...ndicated in the option you have chosen 3 4 end 7 sec n NEW 5 sec 3 After about 7 seconds the motor performs a number of movements equal to the number of pulses entered On the NEW transmitter select the button you want to memorise hold it down and release it after 5 seconds count 3 movements transmitter memo rised If the system makes 6 movements mem ory locked or full transmitter not memorised B 8 ...

Страница 23: ... There are two types of behaviours a the motor stops its movement and completes a brief reversal to free the obstacle b the motor stops its movement 1 2 3 4 x 1 PRG 2 x 1 PRG 2 5 sec 2 Hold down the but ton and count 2 movements Hold down the but ton and count 2 movements Hold down both buttons release them after 5 seconds count 2 movements 4 continues Select the de sired option and program it as ...

Страница 24: ...n of the memory procedure it is necessary to switch the motor off and then on again B 11 1 Procedure run with a memorised transmitter 1 2 3 4 PRG x 1 2 PRG x 1 2 PRG x 1 3 Press and release the button 1 time count 2 movements Press and release the button 1 time count 2 movements Press and release the button 1 time count 3 movements 4 5 PRG x 1 4 Select one of the following potions and execute it o...

Страница 25: ...ter with a PRG button should be used 1 2 3 4 OFF 5 sec ON Disconnect the elec trical power supply to the motor Reconnect the electrical pow er supply to the motor once again 4 5 6 7 NEW 5 sec 2 Hold down the button and release them after 5 sec onds Within 10 seconds 7 8 9 10 OFF 5 sec ON Run procedure B 11 1 in full Disconnect the elec trical power supply to the motor Reconnect the electrical pow ...

Страница 26: ...er s movement including alignments and other effects that are useful especially when multiple roller shutters are installed close to one another with different sizes and rollers of different diameters or for making the shutter s movement more silent The Total manoeuvre duration procedure B 13 and the Roller shutter cruising speed procedure B 12 functions are interdependent the last function set de...

Страница 27: ...t 7 seconds the motor performs a number of movements equal to the number of pulses entered Hold down the button and release it after 5 seconds count 3 movements B B 14 Adjusting the Soft Start Soft Stop movement MONO NOTES AND WARNINGS This procedure can be used to activate adjust or deactivate the Soft Start Soft Stop movement The following options are available function DEACTIVATED 1 2 turn 3 4 ...

Страница 28: ... All procedures require you to use a transmitter memorised in Mode I e g memorised with procedure C 1 or with pro cedure C 2 1 MONO UP STOP DOWN C 1 Memorising the FIRST TRANSMITTER in Mode I MONO UP STOP DOWN NOTES AND WARNINGS This procedure must be used only for memorising the FIRST TRANSMITTER If the motor does not perform the procedure it means that one or more trans mitters are already memor...

Страница 29: ...II Custom mode Procedure C 2 2 memorise a single button on the new transmitter in Mode II i e they associate with the button chosen by the installer one of the commands in the motor s list of commands for details on Mode II see section 4 6 1 Procedures C 2 2 memorise a single button Repeat this operation to memorise another button When performing the procedure you can cancel the programming at any...

Страница 30: ...g the FULL deletion of the memory procedure it is necessary to switch the motor off and then on again When performing the procedure you can cancel the programming at any time by pressing and holding the n and t buttons simultaneously for 4 seconds Alterna tively do not press any button and wait 60 seconds for the motor to complete 6 movements C 4 1 Procedure run with a memorised transmitter 1 2 3 ...

Страница 31: ...nect the power supply C 5 Locking and unlocking the motor s memory MONO UP STOP DOWN NOTES AND WARNINGS Locking the motor s memory stops any other unscheduled or unauthorised transmitters being memorised in it 1 2 3 5 sec 2 5 sec 3 Hold down the but ton and count 2 movements release the button Hold down the but ton and count 3 movements release the button 3 4 5 5 5 sec 3 5 sec 2 Select one of the ...

Страница 32: ...ts defined by the two limit switch heights C 6 1 To program the UP limit switch 0 1 2 3 5 sec 2 5 sec 4 Hold down the button and count 2 movements release the button Hold down the but ton and count 4 move ments release the button 3 4 5 5 sec 2 Command an UP movement 0 Hold down the button and count 2 movements release the button Hold down the button or and wait release the button as soon as the ro...

Страница 33: ...hen performing the procedure at any time you can cancel it by keeping the n and t keys pressed simultaneously for 4 seconds Otherwise do not press any key and wait 60 seconds for the motor to perform 6 movements After the adjustments the s key will command the Raising motion and the key t key will command the Lowering motion The roller shutter will move within the limits defined by the two limit s...

Страница 34: ...wn limit switch 1 defined by the installer 1 2 continues Command an UP movement 0 Command an DOWN movement Hold down the button or and wait wait for the roller shutter to be stopped when it collides with the box UP limit switch position 0 release the but ton Hold down the button or and wait 2 3 1 5 sec 2 release the button as soon as the roller shutter reaches position 1 DOWN limit switch Hold dow...

Страница 35: ...taller with the following procedure The maximum allowed sensitivity level in order to have a reliable application depends on the type weight and dimensions of the roller shutter After changing the setting the automation must complete AT LEAST three complete cycles in order to apply the chosen sensitivity level Warning This function is active with the factory setting but is not applicable if the li...

Страница 36: ...h update function Caution This function is only available if the limit switches have been programmed with the Automatic paragraph B 4 A 4 or C 7 or Semi automatic procedure para graph B 5 A 5 o C 8 This function cannot be disabled Periodically the function activates automatically during an up manoeuvre the roller shutter impacts against the box or other mechanical stop updating the position of the...

Страница 37: ...tter is completely closed no climate sensor is able to open it in au tomatic mode 0 1 5 0 10 15 20 25 35 40 30 45 Klux light intensity automatic operation manual operation momentary drops in light within the hysteresis values drops in light within the under threshold values set threshold value e g 30Klux over threshold hysteresis under threshold active manual commands system deactivated after 2 mi...

Страница 38: ...ion Warning Local legislation may impose heavy fines in the event of legal disposal of this product The product s packaging materials must be disposed of in full compliance with local regulations Technical Characteristics Frequency 433 92 MHz Power emitted 0 dBm Radio coding BD Refer to the technical characteristics stated on the motor s nameplate Note All technical specifications stated herein re...

Страница 39: ...English 38 ...

Страница 40: ...IDV0771A00EN_07 07 2021 www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com ...

Отзывы: