–– GROUP “A” PROCEDURES ––
for motors configured for TWO-WAY communications
Procedures which can only be completed with a Nice transmitter with the
▲
,
■
,
▼
, PRG, ESC keys (eg. “ERA P BD”, “ERA W BD”)
GENERAL WARNINGS RELATING TO THE PROCEDURES
• Before starting any programming, move the roller shutter to an intermediate position, away from the Up and Down limit
switches.
• All the programming procedures must be completed by selecting a single channel on the transmitter.
• If the programming transmitter controls
multiple groups of screen motors
, before sending a command requested by
the procedure, select the group to which the motor being programmed belongs.
• When the motor is powered up, if it makes
2 movements
this means that: at least one transmitter has been memorised
and no limit switch has been programmed; if, on the other hand, it makes
1 movement
this means that: no transmitter
has been memorised.
• When running a procedure, you can abort the procedure at any time by pressing
ESC
(on the back of the transmitter).
• When the Up and Down limit switches are not programmed, the roller shutter can only be commanded in hold-to-run mode
- i.e. you must hold the button down until the roller shutter reaches the desired position. The movement stops when you
release the button in any position.
• When the Up and Down limit switches have been programmed, the roller shutter can be controlled by simply pressing and
releasing the buttons. Doing so starts the movement, which is stopped automatically by the system when the roller shutter
reaches the programmed position.
•
All procedures require you to use a transmitter memorised in “Mode I” (e.g., memorised with procedure A.1 or with pro-
cedure A.7).
•
The “deletion carried out with a non-memorised transmitter” procedure does not appear in this section as, for motors con-
figured in TWO-WAY communication mode, it is always possible to access it by completing the “Memorising the FIRST
TRANSMITTER A.1” procedure.
•
To change the motor’s configuration (from ONE-WAY to TWO-WAY and inversely), it is necessary to perform the “TO-
TAL deletion of the memory” procedure (B.11 motor configured for ONE-WAY communication, A.10 motor configured for
TWO-WAY communication or C.4 motor configured for ONE-WAY communication and OLD generation transmitter, lack-
ing the PRG and ESC buttons) and then switch the motor off and on again.
BiDi
A.1 - Memorising the FIRST TRANSMITTER (in “Mode I”)
BiDi
NOTES AND WARNINGS
• To memorise further transmitters, use the procedure described under section B.7 (motor configured for ONE-WAY communication), A.7 (motor configured for TWO-
WAY communication) or C.2 (motor configured for ONE-WAY communication and OLD generation transmitter lacking the PRG and ESC keys).
• If all transmitters memorised in the motor are deleted, the first transmitter you memorise thereafter must be memorised with this procedure.
• If the installation has multiple motors, the procedure must be repeated for each motor separately.
• On completing this procedure, button
▲
will Raise the roller shutter, button
▼
Lower it, and button
■
Stop the movement.
• If within the transmitter’s range there are multiple powered up motors, to memorise the first transmitter in any one of them,
it is not necessary to disconnect power
to all other motors
; simply proceed as follows.
1
2
3
4
ON
1
PRG
=
5
sec
PRG
Move the roller
shutter to a half-
way position.
Switch on
mains power,
count 1 movement.
Hold down the but-
ton and
release it after
5
seconds
;
over the next 2 minutes
, all motors within the transmitter’s
range in which no transmitters have yet been memorised will
move their awnings up and down, for random periods of time.
4
5
!!!
(x
1
)
Select the roller shutter you wish to program and,
at
the start of an UP movement
, stop it IMMEDIATE-
LY, by pressing and releasing the button (
1 time
):
the movement will
stop briefly (= com-
mand received) and ...
... the roller shutter will resume its up and down movements,
each of random duration.
A
7
– English