A.2 - Temporarily deactivating (and reactivating) motors you do not wish to program
BiDi
NOTES AND WARNINGS
•
This procedure temporarily deactivates (for 5 minutes) only motors whose up and down limit switches have already been programmed.
A.2.1 - To temporarily deactivate motors you do not wish to program
1
2
end
(x
1
)
ESC
“
0
”
The system locks out only those motors whose lim-
it switches have already been programmed. It has
no effect on motors which have not yet been pro-
grammed.
The deactivation is temporary and lasts for 5
minutes.
Press and release
the button (
1 time
);
press and release the
button;
you will see a brief down movement
and a movement which stops the roller
shutter at the Up limit “0”.
For a period of 5 minutes, the locked out motors will
not respond to commands.
A.2.2 - To reactivate temporarily locked out motors
You can reactivate the motors in two ways:
option –
A
1
end
After 5 minutes
the locked
out motors are automatically
reactivated by the system.
Wait for
5 minutes
...
... the system will then move the
roller shutter to the mid position.
option –
B
1
end
During the 5 minute peri-
od
the locked out motors can
be reactivated at any time by
the user.
(x
1
)
ESC
During the
5 minutes
, at any
time...
Press and release
the button (
1 time
);
press and release the
button;
... the system will then move the
roller shutter to the mid position.
A
5
end
!!!
(x
1
)
3
Observe the same roller shutter and,
at the start of
a DOWN movement
, stop the movement IMMEDI-
ATELY, by pressing and releasing the button (
1 time
):
the movement will
stop;
count 3 movements.
English –