QUICK GUIDE
Do not install the unit unless you have read all the instructions through at least once!
Do not install the unit without the “Mechanical travel stops”!
Once the gearmotors, control devices (key selector or push button panel) and safety devices (emergency stop, photocells,
sensitive edges and flashing lights) have been installed, connect the unit as illustrated in the following diagram:
If the gate has only one motor, connect it to motor 2 output on the unit and cut the jumper; leave the terminals of motor 1 and
relative encoder free.
Turn the unit on and check that voltage between terminals 1-2 is 230 Vac and 24 Vdc between terminals 28-29. The LEDs on
the active inputs should be on and the OK LED should flash at 1-second intervals. The encoder LEDs signal each movement
of the 2 motors.
Check movement direction by pressing the CLOSE button on the card:
Wait for motors 1 and 2 to start in closing (motor 2
starts after motor 1 has finished the manoeuvre).
Should either or both motors start the opening manoeuvre, reverse motor connections (terminals 7-8 or 9-10).
Activate the automatic distance search by setting the dip switches as indicated:
Press the CLOSE button on the card and wait for the automatic distance search procedure to be carried out.
Once finished, set the PROGRAMMING dip switches OFF and the FUNCTIONS dip switch as required (ON activates the
function)
Switch 1-2 :
Off Of
= “Hold to Run Control” Functioning
On Of
= “Semiautomatic” Functioning
Off On
= “Automatic” Functioning ( Automatic Closing )
On On
= “Aut Close Always” Functioning
Switch 3
On
= Condominium Functioning ( Not available in the Manual mode )
Switch 4
On
= Preflashing
Switch 5
On
= Water hammer
Switch 6
On
= Closes immediately after Photocell if in Automatic or closes after semiautomatic Photocell
Switch 7
On
= Photocell1 safety also in opening
Switch 8
On
= Photocell test activation (only with photocells connected to terminals 23..27)
Switch 9
On
= CLOSE becomes Pedestrian Open
Switch 10
On
= Courtesy light on flashing light
In the automatic functioning mode, pause time is set at 30 seconds (Switch 2 ON). To change it see Chap. 6.7
Adjust the 2 amperometric trimmers until the triggering thresholds of the anti-crush clutch are reached, as required by law.
20
CH
AP
>> <<
AERIAL
2ND RADIO CH
44 43 42 41
CLOSE
INPUT LED
“PER” CARD
OPEN
RADIO CARD
PROGRAMMING
DIP SWITCH (11-12)
FUNCTIONS
DIP SWITCH
(1...10)
MOTOR 2
AMPEROMETRIC
PROTECTION
MOTOR 1
AMPEROMETRIC
PROTECTION
LED
"OK"
ENCODER LED
MICROPROCESSOR
CHARGE CARD
F3
F2
F1
COMMON
MOT 1
MOT 2
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
TXA
RXA
TXB
RXB
M
M
NEUTRAL
PHASE
CLOSE
OPEN
STEP BY STEP
PHO
TOCELL 1
PHO
TOCELL
ST
OP
G.O
. INDICA
TOR
COMMON (24 V)
+24VDC
MAX 200 MA
PHO
TOCELL B TX
PHO
TOCELL A TX
PHO
TOCELL B RX
PHO
TOCELL A RX
PHO
TOCELL COMMON
12 V ELECTRIC LOCK
M2 ENCODER
M1 ENCODER
MO
TORS’
EAR
TH
M2 MO
TOR
M1 MO
TOR
24 VDC 25 W
LUCY FLASHING LIGHT
220-230 V
A
C PO
WER
SUPPL
Y 50-60 HZ
M1 M2
1 2 3 4 5 6 7 8 9 10
11 12
1 2 3 4 5 6 7 8 9 10
11 12
Switch 10 "OFF" recommended
for "PLUTO"
(Slowing down during closing
manoeuvres short)
Switch 10 "ON" recommended
for "METRO"
(Slowing down during closing
manoeuvres long)