8
– English
EN
This “indicator” functions in the following way:
- off when the safety chain is open (ALT inp, red STOP button, thermal protec-
tion or release)
- flashes 0.5 s ON, 0.5 s OFF when it works properly
- shows the same diagnostics as the red L1 WARNING LED when there are
“serious errors” (Paragraph 6.2).
Setting the pause time for automatic closing
1
Set DIP switches 3 and 4 to ON.
2
Send a command to open the gate so as to move the gate to its fully open
position.
3
Once this position is reached, wait for a period of time equal to the required
pause time for automatic closing and then command the gate to close. The
pause time for automatic closing is now saved.
In order to change the pause time, set dip 3 and 4 to OFF and then back to ON.
At this point you must repeat the sequence of opening, pause time and closing.
CAUTION! -
When DIP switch 4 is moved to the OFF position, the pause time
is deleted.
6.2 - Diagnostics
Some devices are equipped to display messages to identify their status and faults. The following table describes the various alarm signals according to the type
of problem. These alarm signals are provided by appropriate flashes of the green OK L2 LED and the red WARNING L1 LED and from the flashing light (if there
is one) connected to the specially programmed control unit outputs.
DIAGNOSTICS GREEN OK L2 LED
Signal
Cause
Solution
Flashing light
2 flashes - short pause
2 flashes - long pause
Triggering of a photocell
At the start of the manoeuvre, one or more photocells fail to give the
enable signal; check for obstacles and whether the photocells are in-
terfering with each other’s IR. When the safety devices have intervened,
the automation can be controlled with a person present through the
wired controls. It is not possible to send commands via radio.
Flash
4 flashes - short pause
4 flashes - long pause
Triggering of the STOP input
At the start of or during the manoeuvre, the STOP or ALT input was
triggered; identify the cause. When the safety devices have intervened,
the automation can be controlled with a person present through the
wired controls. It is not possible to send commands via radio.
Flash
6 flashes - short pause
6 flashes - long pause
Manoeuvre limiting device
---
Flash
9 flashes - short pause
9 flashes - long pause
Automation system locked
Send the “Release Automation” command or command the
manoeuvre with “Step-by-Step High Priority”.
Flash
The LEDs come on for 3
seconds
Lock automation
---
Flash
2 flashes of 1 second with
pause of 1.5 seconds
Automation system released
---
Flash
DIAGNOSTICS RED WARNING L1 LED
Certain signals can be cancelled by pressing the red STOP button
Signal
Cause
Solution
Flashing light
5 flashes - short pause
5 flashes - long pause
EEPROM error - Error in the
internal parameters of the control
unit
Disconnect and reconnect the power supply. If the error persists, run
the “Total deletion of the control unit memory” (paragraph 3.8) and
rerun installation. If the condition persists, there may be a serious
fault and you will need to replace the electronic circuit board.
Flash
2 flashes - short pause
2 flashes - long pause
Safety Test Error
Rerun the recognition procedure for the safety devices connected to
the control unit (paragraph 3.9).
---
3 flashes - short pause
3 flashes - long pause
Error in direction of rotation
of the Encoder Or inverted limit
switch
Reverse the direction of rotation of the encoder by moving DIP switch
2 to ON (see paragraph 3.10). If the motor mounts a mechanical limit
switch, reset the error by pressing the STOP button and invert the
opening limit switch connection with that of the closing limit switch
at the LIMIT SWITCH terminal (
Fig. A
-
page
4
).
4 flashes - short pause
4 flashes - long pause
Error with safety limit switches
The gate has gone past the safety limit switches during Opening
or Closing. Move the gate manually to about half way up using the
emergency manoeuvre system (see the manual of the motor) and
press the STOP button on the cover in order to restore operation.
Assess whether you need to change the previously acquired Open-
ing/Closing positions.
---
6 flashes - short pause
6 flashes - long pause
Error with contactor
Disconnect all the power lines for a few seconds, then try sending a
command again; if the problem persists, there may be a serious fault
on the circuit board or on the connections of the motor. Carry out
checks and replace parts, if required.
---
7 flashes - short pause
7 flashes - long pause
RS485 communication error on
Encoder
Check that the motor-control unit cable is connected correctly, in
particular the encoder cable (6 coloured wires).
---
8 flashes - short pause
8 flashes - long pause
Encoder error
Check that the motor-control unit cable is connected correctly, in
particular the encoder cable (6 coloured wires). Rerun the recogni-
tion procedure of the Opening and Closing positions.
---
9 flashes - short pause
9 flashes - long pause
Error in limit switch acquisition
Repeat the recognition procedure of the Opening and Closing posi-
tions.
---
Содержание DPRO500
Страница 16: ......
Страница 28: ......
Страница 40: ......
Страница 52: ......
Страница 64: ......
Страница 76: ......
Страница 89: ...RU 1 III Nice A 70 A 1 5...
Страница 98: ...RU 10 7 L1 warning 6 2 STOP 108 5 FM 230 400 PP 6 2 V W V W L1 WARNING 9 3 9 3 10 8...
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ...www niceforyou com Nice S p A Via Pezza Alta 13 31046 Oderzo TV Italy info niceforyou com IS0639A00MM_24 01 2018...