103
LINELOCK INPUT
Required if Low Frequency Fluorescent Lighting is utilized in the installation
The T-
DAR™ system requires an input of low voltage AC from a source that also
supplies the lighting for the installation (as shown in the diagram below). This low
voltage (6 to 30VAC) AC signal is required to allow the cameras to be in sync with
the low frequency fluorescent lighting. Failure to provide this signal to the T-DAR
may cause erratic behavior in the system.
Any 6 to 30VAC signal will provide the required synchronization of the T-DAR to the
low frequency fluorescent lighting. A small transformer is provided with the T-DAR
system and can be used to provide this signal; in addition, any other source of low
voltage AC (6 to 30VAC) that is available can also be utilized. Low voltage DC will
not provide the required LineLock signal; use low voltage AC only.
CAUTION!
Do
not
provide 110/220 VAC to the T-DAR unit LineLock input. This will damage the
unit.
About Fluorescent Lighting:
Older style fluorescent lights turn on and off the light output at the AC line frequency: 50 or 60 Hz-depending on the area of the
world. Since cameras operate at a similar frequency, this rapid cycling on and off of the lights can cause erratic behavior in the
T-DAR cameras and requires synchronization.
Newer style high frequency fluorescent lights operate at much higher frequencies than do the T-DAR cameras and do not
affect the T-DAR cameras; no LineLock signal is required.
Содержание T-DAR T1010MT
Страница 16: ...9 Figure 2 T DAR Control Unit CAD ...
Страница 18: ...11 Figure 4 T DAR Annunciator CAD ...
Страница 20: ...13 Figure 6 T DAR Stereo Tracking Head ...
Страница 22: ...15 FFigure 8 T DAR Door Encoder ...
Страница 24: ...17 Figure 12a T DAR Camera Cable Extender Amplifier CAD ...
Страница 26: ...19 Figure 13 T DAR Annunciator Encoder Cable Extender CAD ...
Страница 28: ...21 WMK 100 Camera Head Wall Mount Figure 15a WMK 100 Camera Head Wall Mount ...
Страница 29: ...22 CMK 100 Camera Head Ceiling Mount 15b CMK 100 Camera Head Ceiling Mount ...
Страница 97: ...90 Control Unit Panel Connections Figure 35 Control Unit Connections Front Panel Upper Panel ...
Страница 108: ...101 ...