48
Configuring the T-DAR
The T-DAR user interface (UI) is used to set-up and optimize the detection
performance of the system. The following instructions provide guidelines that
will enable the installer to quickly and effectively place the T-DAR system in
service.
Viewing Images
The installer should select the Show Camera Views view from the monitor
page. This will display a
“four view” image on the CCTV monitor showing the
tracking image, event camera video, and tracking camera views
‘a’ (1) and ‘b’
(2) from a single camera head. Using this image, the installer is able to clearly
see what the system is viewing in real time. Images from the secure door or
the public door may be shown, independently.
Calibration
After the unit has been installed and the UI is connected to the unit, a
calibration must be performed.
The purpose of the calibration is to ‘teach’ the
system what the area of detection looks like when the area is empty of people.
The secure camera head (camera 1) and the public camera head (camera 2)
will both need to be calibrated. Objects that are not normally in the scene
such as carts and parcels should be removed before the calibration is
performed. This clean calibration will then allow the system to recognize
objects introduced into the scene and track them accordingly while ignoring
those objects that are normal to the scene.
Inward Swinging Public Door
The following describes the process for performing calibration when an
inward swinging door sensor (door encoder) is used. An inward swinging door
swings under the view of the camera head. A door sensor is not required on
the secure door of the mantrap. After the door sensor has been terminated at
the Control Unit, it should be powered up and tested. On the monitor page,
select I/O Display and choose Public Door from the drop down menu. Test
the door sensor by slowly moving the arm back and forth. This should result
in a change in the sensor value shown at the bottom of the CCTV monitor
display. If no change occurs in the current sensor values, as the door is
swung, check to be sure the wiring is terminated at the proper inputs.
To calibrate the door, follow the instructions on the screen when the
Calibration button is clicked.
Be sure that ‘Inward Swinging’ is checked on the
Initial Setup tab, for the public door.
‘Inward Swinging’ should be unchecked
for the secure door. After calibration, verify that the tracking image is
calibrated successfully (black image). Verify that the door is removed from the
image as it is swung though its full range of motion from open to closed. The
door should be blacked out at every possible position.
Содержание T-DAR T1010MT
Страница 16: ...9 Figure 2 T DAR Control Unit CAD ...
Страница 18: ...11 Figure 4 T DAR Annunciator CAD ...
Страница 20: ...13 Figure 6 T DAR Stereo Tracking Head ...
Страница 22: ...15 FFigure 8 T DAR Door Encoder ...
Страница 24: ...17 Figure 12a T DAR Camera Cable Extender Amplifier CAD ...
Страница 26: ...19 Figure 13 T DAR Annunciator Encoder Cable Extender CAD ...
Страница 28: ...21 WMK 100 Camera Head Wall Mount Figure 15a WMK 100 Camera Head Wall Mount ...
Страница 29: ...22 CMK 100 Camera Head Ceiling Mount 15b CMK 100 Camera Head Ceiling Mount ...
Страница 97: ...90 Control Unit Panel Connections Figure 35 Control Unit Connections Front Panel Upper Panel ...
Страница 108: ...101 ...