73
Outputs
There are six relays on a CB-210 for connecting signals from the T-DAR. The first
relay is for the secure door lock,
Relay
1A
and
Relay
1B
. The second relay is for the
public door lock,
Relay
2A
and
Relay 2B
. Relays four through six are for the tailgate
alarm and forced door alarm. Activating the relay is caused by enabling the selected
relay number to make contact when an alarm event is present.
For example selecting
Forced door alarm sets outputs
check box 4, enables
Relay 4
to close when either the public or secure door is forced open. Likewise,
when
Multiple people public entry
check box 5 is checked,
Relay 5
will close
when tailgating occurs.
Setting triggering events for both doors independently is not possible. Otherwise,
any combination of relays and triggering events may be selected. There is no
specification as to how the relays are to be implemented. Regardless of whatever
the control situation dictates there are three ways to close any of the relays.
Change Administrator Password
Use the same process as changing
Installer Password.
If the administrator
password becomes lost contact the T-DAR system installer or Newton Security, Inc.
Change Installer Password
Figure 29 - Installer Password
Содержание T-DAR T1010MT
Страница 16: ...9 Figure 2 T DAR Control Unit CAD ...
Страница 18: ...11 Figure 4 T DAR Annunciator CAD ...
Страница 20: ...13 Figure 6 T DAR Stereo Tracking Head ...
Страница 22: ...15 FFigure 8 T DAR Door Encoder ...
Страница 24: ...17 Figure 12a T DAR Camera Cable Extender Amplifier CAD ...
Страница 26: ...19 Figure 13 T DAR Annunciator Encoder Cable Extender CAD ...
Страница 28: ...21 WMK 100 Camera Head Wall Mount Figure 15a WMK 100 Camera Head Wall Mount ...
Страница 29: ...22 CMK 100 Camera Head Ceiling Mount 15b CMK 100 Camera Head Ceiling Mount ...
Страница 97: ...90 Control Unit Panel Connections Figure 35 Control Unit Connections Front Panel Upper Panel ...
Страница 108: ...101 ...