72
Door Control
The configurable options of the
Door Control
section allow for adapting T-DAR to
the existing peripherals to correctly trigger the unit. The logic state for these devices,
as used by the T-DAR, is selected by clicking the check box that reflects the
installation. For example, if the door contact passes continuity when the door is
closed the door contact is said to be
closed
when the door is closed. The same
logic is true for the
Access Contact
and the
Alarm Reset
. If there is some question
about the setting here, use the following steps to diagnose the issue:
Door Contact
On the monitor tab, observe the count for door opens (reset the counts on the
setup I/O page if necessary).
Open and hold the door.
If the door opens count increments by one, the switch is set correctly.
If the door open count does not increment, close the door.
If the door open count increments now, then the switch is set incorrectly.
o
If the count does not ever change, switch the display mode to Show /O
and observe the display of the I/O function on the screen. I/O
assignments can be seen in Figure XX, page XX.
o
If no changes are observed on the screen during testing, verify wiring
of device and controller.
Set the switch correctly and re-test.
Valid Access Contact
On the monitor tab, observe the count for Valid Access Contact (reset the
counts on the setup I/O page if necessary).
Perform a Secure Door, Public or Secure Side Valid Access Grant.
If the Valid Access Contact count increments by one immediately, the switch
is set correctly.
If the Valid Access Contact count does not increment immediately, but takes
a second or more to increment, the switch is set incorrectly.
o
If the count does not ever change, switch the display mode to Show
I/O and observe the display of the I/O function on the screen
o
If no changes are observed on the screen during testing, verify wiring
of device and controller.
Set the switch correctly and re-test.
Содержание T-DAR T1010MT
Страница 16: ...9 Figure 2 T DAR Control Unit CAD ...
Страница 18: ...11 Figure 4 T DAR Annunciator CAD ...
Страница 20: ...13 Figure 6 T DAR Stereo Tracking Head ...
Страница 22: ...15 FFigure 8 T DAR Door Encoder ...
Страница 24: ...17 Figure 12a T DAR Camera Cable Extender Amplifier CAD ...
Страница 26: ...19 Figure 13 T DAR Annunciator Encoder Cable Extender CAD ...
Страница 28: ...21 WMK 100 Camera Head Wall Mount Figure 15a WMK 100 Camera Head Wall Mount ...
Страница 29: ...22 CMK 100 Camera Head Ceiling Mount 15b CMK 100 Camera Head Ceiling Mount ...
Страница 97: ...90 Control Unit Panel Connections Figure 35 Control Unit Connections Front Panel Upper Panel ...
Страница 108: ...101 ...