© 2021 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
85
ELECTRICAL
This article provides an overview of the purpose and function of a GFCI outlet.
Ground Fault Circuit Interrupt Outlets (GFCI)
The Ground Fault Circuit Interrupt (GFCI)
outlets protect the user from ground
faults between a hot wire and ground.
The 120 Volt electrical outlets in the
kitchen and bath area are GFCI protected
receptacles. The electrical outlets located
in the slideouts are wired through the
kitchen GFCI.
The exterior electrical outlets are wired
through the bathroom GFCI. On units
equipped with the floor heat option, a separate GFCI is
installed in the bathroom or near the main breaker box.
Units with the holding tank heat pad option will have an
additional GFCI located in the basement area; however,
the exact location varies.
Testing The GFCI Outlets
The GFCI outlets should be tested at least once a month.
The reset button needs to be pressed before starting the
test.
1. The GFCI outlet must be supplied with 120V power
for testing and general use.
2. Pressing the Test button on the GFCI outlet will trip
and cease to supply power to the outlets on the
GFCI, as well as any other outlets that are hooked up
downstream of the GFCI outlet.
3. Pressing the Reset button will reset the GFCI outlet
and all outlets downstream of the outlet. Some GFCI
outlets may have a LED light as a visual indicator of
the power status.
4. If a tripped GFCI outlet will not reset, disconnect
everything plugged into them or hooked up
downstream; then try resetting the GFCI again.
5. If all loads are disconnected and 120V power is
present to the GFCI outlet and the GFCI outlet will still
not reset, it may require service or replacement by a
qualified technician.
If the GFCI is working properly, the reset button will
remain in the “IN” position. If an item plugged into a
slideout or outside receptacle is not working, check for
a tripped GFCI in the kitchen or bathroom. Likewise, if
the floor heat or holding tank heat pads are not working,
check the GFCI for that circuit.
The GFCI will not reduce the shock hazard if the short
is between a neutral and hot wire or two hot load
wires.
WARNING
!
BrandMotion FreedomCharge MAX Qi Wireless Dash Charger
(Model: FDMC-1312)
This article provides an overview of the BrandMotion Dash Wireless Charging Station (Models: FDMC-1312), which may be
built-in to the dash or cockpit area.
Charging your phone has never been easier.
FreedomCharge uses the wireless charging standard, Qi,
to keep your phone going without the hassle of plugging
it in. This type of charging has taken off with use in homes,
but not until recently have you been able to get this
convenient and easy to use technology in your vehicle.
Some coaches may have more than one wireless charging
station installed; however, the size and shape of the
charging area may vary. Some chargers may be mat-style
(flat on a driver or passenger side console), and some may
be vertically installed as a bucket-style.
Operation
The wireless charging stations typically turn on at the
same time as the battery disconnect. Dash-mounted
chargers are powered from the fuse panel in the shore
cord compartment (usually the USB F18 fuse). Some early
production 2021 coaches may have used the Radio/
AutoGenStart F13 fuse.
It works by using inductive charging technology to allow
your smartphone to charge without connecting a charger.
No longer will you have to search for your charger and
orient it the correct way just to plug in your phone. Add a
new level of convenience to your car and keep your eyes
on the road, instead of fumbling with a tangled mess of
cords. When a compatible device is placed on top of the
charger, the audible tone sounds as the charger begins
to charge phone, and the phone will also indicate it is
charging. The updated triple coil allows charging through
most thick cases, including Otterbox.
Содержание Mountain Aire 2022