© 2021 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
202
SLIDEOUTS
3. Move to the other room extension mechanism, and
rotate the threaded rod clockwise 12 complete turns.
4. Return to the first room extension mechanism, and
rotate the threaded rod clockwise 12 complete turns.
5. Repeat steps three and four, alternating from
mechanism to mechanism, rotating each threaded rod
12 complete turns until room is sealed. Do not exceed
15 ft. lbs. Make sure the room does not bind.
If at any stage something is not understood, or if the
room begins to bind, do not force the room. Contact
Newmar Customer Support for assistance.
IMPORTANT
!
Leave the solenoid valves open, the lift bolts and
threaded rods in place until the room has been
serviced.
NOTICE
!
If at any stage something is not understood, or if the
room begins to bind, do not force the room. Contact
Newmar Customer Support for assistance.
IMPORTANT
!
Do not extend the room until the room has been
serviced. Any solenoid valves left open should be
closed. The threaded rods should be completely
removed before room is fully extended. If there is
not enough room to remove both threaded rods
completely, alternate backing the threaded rods out
and slightly extending the room. Be careful to not
extend the room so far that the threaded rods impact
the coach wall or the mechanism.
IMPORTANT
!
EXTENDING ROOM AFTER SERVICE
1. Room lift bolts should not be retracted yet. Push
and hold the room switch to “retract” for five to ten
seconds.
2. Push the room switch to “extend” until the room is
within one inch of being fully extended. Threaded
rods should be completely removed at this time. Do
not allow room to bind.
Source(s): Universal Platform Level-Out Room Extension Mechanism Manual Room
Lift Procedures and http://www.hwh.com/ml55155.pdf as adapted for Newmar
Corporation v.09NOV15.
Product(s): This source is associated with more than one product. Refer to Newgle
for more information about the product(s) offered for your coach’s model year.
3. Retract all lift bolts completely. If room starts to drop,
alternate between lift bolts evenly while turning lift
bolts.
4. After lift bolts are retracted, push room switch to
“extend” until room is fully extended and down. If
room dropped while retracting lift bolts, push room
switch to “extend” for five to ten seconds.
5. Retract room with room switch.
Содержание Mountain Aire 2022
Страница 1: ...SM 2022...