80
ELECTRICAL
Service Required Indicator:
1. The generator switch indicator light may flash in a
series of three quick flashes, followed by a short
pause, and then quickly flash three more times. These
flashes indicate that service is required.
2. Refer to the owner’s manual for your specific
generator for more in-depth descriptions of flashing
codes.
Excessive cranking can damage the starter motor.
Do not crank the generator more than 30 seconds at
a time, and allow at least two minutes before trying
again if the first attempt fails.
IMPORTANT
!
CAUTION
!
Failure to turn off the 120 volt appliances when
starting or stopping the generator may damage the
transfer switch and/or electrical appliances.
If your coach contains an Energy Management System,
8kw generator, and three roof air conditioners, the
combined load may exceed the capabilities of the
generator. Please remember to turn off one of the air
conditioners as the 8kw generator is not intended to
run all three roof air conditioners at the same time.
NOTICE
!
How To Operate The Hydraulic Generator Slide
WARNING
!
It is critical that the AGS system be turned off
any time the generator is going to be serviced.
Failure to deactivate the AGS system may result in
damage, injury, or death if the Genset should start
unexpectedly. Also, if the AGS system is set and
the generator is turned off at any switch, it will
clear the AGS settings.
BEFORE STARTING THE GENERATOR:
1. Turn off the air conditioners and any other large
electrical loads, as recommended by the generator
manufacturer.
2. If the generator previously ran out of fuel, add fuel to
the tank.
3. Prime the generator by holding the generator switch
in the stop position.
TO START THE GENERATOR:
1. Press and hold the generator start switch in the “Start/
Preheat” position. It will automatically delay and pre-
heat.
2. The indicator light will flash rapidly while pre-heating,
and the generator will crank and start.
3. When the generator starts, release the switch.
4. The indicator light will stay illuminated while the
generator is running.
TO STOP THE GENERATOR:
1. Press the generator switch in the “Stop” position.
2. Release the switch.
3. The indicator light will turn off when the generator
stops.
The generator in your coach runs on the
same diesel fuel as your main engine. The
diesel fuel is drawn through a separate
supply tube that is positioned in the tank in
a manner that will not allow the generator
to draw fuel and run if the tank level dips
below the ¼ level.
Depending on the ambient temperatures,
the generator may pre-heat prior to
cranking. This pre-heat condition is noted
by flashing the light on the generator start
switch until the cycle is complete (up to 15
seconds). Once it has pre-heated sufficiently, the starter
will engage and the engine will start.
To Operate The HWH
Hydraulic Generator Slide:
1. Turn on the ignition key.
2. Open the compartment located in front of the first
wheel on the driver’s side.
3. Locate the generator slide switch.
4. Press and hold the switch in the “extend” position
until the generator slide reaches the desired position
or maximum extension.