Chapter 5: User Tests
10G Wired Performance Test (Y.1564)
117
to learn more.
Configuration
Network performance is measured between two points.
Therefore, configuration includes setting up both the source and
end-point analyzers. For this test:
The source is the OneTouch AT 10G analyzer on which the test
is configured and controlled.
The endpoint is an OptiView XG that is appropriately
connected and configured to receive instructions from a
OneTouch AT 10G.
The OneTouch AT 10G tester initially operates as the controller,
then transfers control to the OptiView XG - the OneTouch then
operates as a Performance Peer. Note that separate upstream and
downstream measurements are shown for throughput, frames
lost, and jitter, while latency shows results based on round-trip
traffic / packets.