10-4
Netopia ISDN Router Reference Guide
Loopback Test PASSED.
The loopback test was successful. The
line is working properly, and the director y numbers (the ISDN phone
numbers associated with each B-channel) are correct. If a SPID is
associated with the first B-channel, its correctness is also
confirmed. If a SPID is associated with the second B-channel, its
correctness is confirmed.
Note:
SPIDs are applicable to cer tain Nor th American ISDN switch
protocols.
If the loopback test fails
Follow these suggestions to track down the reason behind the
loopback test’s failure:
■
Check that the SYNC LED is glowing a solid green.
■
Check the ISDN event log and get more information about
events that seem relevant to the failure.
■
Checking the B-channel usage in the Quick View screen to
make sure there were no incoming calls when the loopback test
was per formed.
■
Check the accuracy of the director y numbers, SPIDS, and
switch protocol you entered in the ISDN Line Configuration
screen (compare them with the information you received from
your telephone company).
■
Switch on termination of the S/T bus.
■
Contact your telephone company to have the line checked.