![Nemox gelato 15K crea Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/nemox/gelato-15k-crea/gelato-15k-crea_instruction-book_3946261014.webp)
blade) and the bush (17) from the paddle.
•Separate the ORs gaskets from the bush
(17), from the tap (9) and from the ring (4).
•Fill 2 separated baskets with sanitizing
solution and fully immerse in the first
basket for the time required by the
disinfecting agent (no less than 5 minutes)
the paddle (5), the inserts (18), (19) and
(21), the buffers (20), the tap (9), the ring
(4), the spoon (23), the lid (3), the lid cap
(3a) and his rubber small cap and all the
ORs gaskets.
•By using the hard bristle pipe cleaner (22)
or any other appropriate tool, carefully
clean the body and the recessed and/or
hidden areas of the paddle (5). Pay utmost
attention in cleaning the internal sleeve, the
b l a d e s a n d t h e z o n e a r o u n d t h e
interlocking buffers (20). Leave it fully
immersed in the second basket with the
solution prepared above for the time
required (no less than 5 minutes).
•By using the hard bristle pipe cleaner (22)
or any other appropriate tool, carefully
clean the body and the recessed and/or
hidden areas of the bush (17) and the tap
(9). Pay utmost attention in cleaning the
ORs throats. Leave them all fully immersed
in the second basket with the solution
prepared above for the time required (no
less than 5 minutes).
•By using the hard bristle pipe cleaner (22)
or any other appropriate tool, carefully
clean the body and the recessed and
hidden areas of the retainer (4). Pay utmost
attention in cleaning the OR throat and the
thread. Leave it fully immersed in the
second basket with the solution prepared
above for the time required (no less than 5
minutes).
•By using the hard bristle pipe cleaner (22)
or any other appropriate tool, carefully
clean the body and the recessed and
hidden areas of the inserts (18), (19) and
(21), especially the zones where the metal
blade of the paddle gets stuck. Repeat the
operation twice. Fully immerse the parts
each time into an unused disinfecting
agent solution. Leave them all fully
immersed in the second basket with the
solution prepared above for the time
required (no less than 5 minutes).
•By using the wet cloth previously
immersed in the sanitizing solution,
carefully clean all the ORs gaskets, the
interlocking buffers (20), the lid (3), the lid
cap (3a) and the silicon cap. Leave them all
fully immersed in the second basket with
the solution prepared above for the time
required (no less than 5 minutes).
•By using the wet cloth previously
immersed in the sanitizing solution,
carefully apply the disinfecting agent on all
other parts of the machine that can coming
in contact with food. In order to carry out
the various operations correctly, you must
proceed from up downwards, finishing
with the floor. Leave the disinfecting agent
to act for the contact time required (no less
than 5 minutes). If left less time than
required, disinfection may be ineffective.
•For the vertical enclosures of the machines
and all the zones not in contact with food,
use a disposable towel wet with the
sanitizer and wipe down all the surfaces of
the machine.
•After applying disinfecting agent, remove
residues with a final potable water rinse. If
you use a suggested Stera-Sheen™ Green
Label sanitizer as per suggested dosage
(see the paragraph of the DISINFECTION
section) you can avoid rinsing. Repeat the
sanitizing operation twice in order to avoid
any bacteria growth.
•Dry thoroughly with a disposable towel the
surfaces to avoid bacteria proliferation due
to moisture.
•Pull out from the basket all the removable
parts and dry them with a disposable
towel. Remount all the gaskets and
reposition the pieces on the machine.
•We recommend you alternate every 6
months the type of disinfecting agent to
avoid developing resistant forms of
bacteria. Bacteria spores are the most
resistant biological forms and, therefore, it
is recommended you use chloride-based
products.
ACTION
BLADE ACTIVATION
COMPRESSOR ACTIVATION
PROGRAM ACTIVATION
PRESERVATION ACTIVATION
TURN OFF FROM PROGRAM
TURN OFF FROM CONSERVATION
PROGRAM CHANGE
CONSERVATION CHANGE
PROGRAM ACTIVATION FROM CONSERVATION*
PROGRAM ACTIVATION FROM CONSERVATION***
KEY COMBINATION
2
1
11
1+2 (3 seconds)
11 (3 seconds) then 1 and 2
11 (3 seconds)
11
12
11**
11
* If conservation is activated after a program.
** To activate the program whose LED is flashing, first select a different program.
*** If conservation is activated without running programs.
English
TROUBLESHOOTING
•Machine does not cool:
•Check that the power plug is properly
inserted and the appliance has electrical
energy.
•The safety device of the compressor
comes into action: wait 5-10 minutes
before restarting the machine. Rapid and
continued start-up attempts do nothing but
prolong the period of inactivity of the
machine.
•Check that the machine is correctly
positioned with the ventilation grids (6) free
of any obstructions.
•Check that the machine is not running a
preservation cycle (LED (11a,b,c,d)
flashing) that stops the compressor.
•Check that when the machine (switch (10))
turns on, the control panel shows the
correct initialization procedure by turning
on all LEDs in sequence.
•The paddle does not turn:
•Check that the paddle (5) is properly
attached to the tube and locked with a
special locking ring (4).
•Make sure it is free from obstacles that
prevent it from rotating.
•Make sure the lid is closed in the correct
position: a safety device stops the paddle
when the lid is opened.
•Check that the LED paddle (2a) is not
flashing. In this case, press the button (2)
twice to restart the paddle. Make sure that
the mixture is not too thick to prevent the
rotation of the paddle.
•Make sure that the machine is not running
a preservation cycle (LEDs (11a-b-c-d)
flashing) that stops the paddle.
•The machine is noisy:
•Some noise is part of the normal operating
specifications, but if it becomes excessive
contact the Service Centre to avoid further
and more serious problems.
•The water discharge pipe leaks:
•Replace the gaskets of the water
discharge tap (9). Two additional gaskets
sets (16) are provided with the machine.
Lubricate the gaskets before fit the tap (9)
into the water discharge tube.
•The plastic sleeve (17) on the lower part of
the paddle is tto easy to separate.
•Replace the gasket with the new one. Four
additional gasket (15) are provided with
the machine.
•The paddle does not scrape properly the
sides of the bowl.
•Check that the scrapers (18), (19) and (21)
are not damaged or worn.
•Check that the resilient pads (20) are not
distorted. If they are distorted replace them
with new parts. One set is included.
English
15
14