41
Attach the Main Disconnect Switch
to the Roof Inside
the Man-Hatch Opening.
Make Sure there is Clearance
for Stir-Rite III Movement.
If drilling is required, make sure to
properly seal the holes.
Shown as
Reference Only
Figure 51 - Install Electrical Main Disconnect
•
Do Not enter the bin unless power to all of the
equipment has been shut-off and locked out.
Failure to heed this warning could result in
severe personal injury or death!
WARNING
•
A main power disconnect switch capable of
being locked in only the OFF position shall be
provided. This shall be locked any time work is
being done on the equipment.
WARNING
Suspension Chain
(if necessary)
Suspension Chain
(if necessary)
Electrical Power-In
Cord
Safety
Chain
PHASE
AC
VOLTS
# OF DOWN
AUGERS
MAIN DISCONNECT
AMPERAGE REQ’D
1
230
1 - 2
30 AMP
1
230
3 - 4
60 AMP
3
230
1 - 4
30 AMP
3
460
1 - 4
15 AMP
•
Leave the disconnect switch in the OFF
position until all installation is complete,
and while there is any person still in the
bin. Entanglement with augers can cause
severe personal injury or death!
WARNING