Checking and Updating Management firmware Level and the BIOS Level
5-11
Figure 5-9 Management Firmware Updates Page
2. To update the management firmware on the partition, click
Browse
on the firmware
update page, navigate to the location of the saved firmware update file, and click
Load
.
The firmware revision is loaded and distributed to the Service Processor of each
member cell of the partition that is powered on. The update takes several minutes
to complete. Initially, a dialog box is displayed saying that the update is in progress.
When the update finishes, all cells should have the same firmware level. Each
Service Processor performs a reset action, and the connection to the remote
console interface is lost.
3. Refresh the page and log on to restore the partition Web interface.
4. Navigate to the firmware update page and click
Display Current Firmware Status
and Revision
to check that the current management firmware level is correct.
A dialog box appears containing the current management firmware revision level for
each cell in the partition, as shown in
Figure 5-10
. All cells in the partition should
have the same firmware level.
Note: If a cell is not listed in the dialog box, it is AC powered off or otherwise not
communicating properly.
Содержание NECCare Platinum Express5800/A1160
Страница 1: ...EXPRESS5800 A1160 HW Installation Guide ...
Страница 8: ......
Страница 14: ......
Страница 28: ......
Страница 36: ......
Страница 41: ...Power Cabling for 200V to 240V Systems 4 5 4 2 1 Power Strip Cabling for a System with One Cell ...
Страница 42: ...Power Cabling for 200V to 240V Systems 4 6 4 2 2 Power Strip Cabling for a System with Two Cells ...
Страница 52: ......
Страница 76: ... 456 01805 000 ...