CHAPTER 8
Page 171
Revision 3.0
EX- FCCS
EX-FCCS Network Configuration
2.2 Conditions for Network Establishment (NEAX2000 IVS
2
to NEAX2400 IMX Connection)
Conditions for connecting the NEAX2000 IVS
2
to NEAX2400 IMX are described below.
1. All IVS
2
systems must be directly connected to an IMX. See
Figure 8-2
.
Figure 8-2 NEAX2000 IVS
2
to NEAX2400 IMX Connection
2. The number of logical routes available (899) in the FCCS network is reduced by one for every route
provide in the NEAX2000 IVS
2
when connected via Enhanced CCIS.
Note:
The above is a condition of data assignment in the NEAX2400 IMX system. The NEAX2000 IVS
2
system
accommodates up to 255 nodes (including NEAX2400 IMX and NEAX2000 IVS
2
systems). The number of
point codes assignable in the NEAX2000 IVS
2
system is a maximum of 255, including Enhanced CCIS net-
works.
3. When directly connecting a NEAX2000 IVS
2
to a NEAX2400 IMX, one signal channel may support
multiple voice routes. However, when the Enhanced CCIS function is provided with EVENT BASED-
CCIS, a signal route must be provided per voice route.
NEAX2000 IVS
2
(B) cannot be added to NEAX2000 IVS
2
NEAX2400 IMX.
Enhanced CCIS
IMX
IVS
2
(A)
IVS
2
(B)
(A) which is already connected with
UNAVAILABLE
Содержание NEAX 2400 IMX
Страница 43: ...CHAPTER 3 ND 70185 E Page 28 Revision 3 0 This page is for your notes Get other manuals https www bkmanuals com...
Страница 71: ...CHAPTER 4 ND 70185 E Page 56 Revision 3 0 This page is for your notes Get other manuals https www bkmanuals com...
Страница 183: ...CHAPTER 7 ND 70185 E Page 168 Revision 3 0 This page is for your notes Get other manuals https www bkmanuals com...
Страница 213: ...CHAPTER 8 ND 70185 E Page 198 Revision 3 0 This page is for your notes Get other manuals https www bkmanuals com...