CHAPTER 5
ND-70185 (E)
Page 96
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 8:
AFPC
Assign the FCCS routing data.
FPC: 1 (FPC of the adjacent node)FCCH: 1 (with FCCH)
CRT: 10
FCHN: 2
STEP 9:
ACAN
Assign the CIC number to the connection trunk.
FPC: 1
FCIC: 1-664
CLENS: LEN of the connection trunk
STEP 10: AFCD
Assign NAILED DOWN CONNECTION for the connection link established between FCCH and
SDT.
LENS-A: LEN of SDT
EAD-A: 07 (pad off)
LENS-B: LEN of FCCH
EAD-B: 07 (pad off)