CHAPTER 3
NDA-24219
Page 94
Revision 2.0
NAP-200-007
Sheet 45/55
Termination of Cables on MDF
•
Install the PZ-8PFTA card to the PIM according to the following steps.
STEP 2:
Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on the PZ-8PFTA
card as shown in
. Then, secure them to each other using screws and tie wraps.
Figure 007-34 Connection of 25-Pair Cable and PZ-8PFTA
+
+
TO MDF
(SEE STEP 3)
25-PAIR CABLE
CHAMP CONNECTOR (PROVIDED WITH PZ-8PFTA)
PFT0 CONNECTOR
PFT1 CONNECTOR
PZ-8PFTA
+
+