CHAPTER 3
NDA-24219
Page 80
Revision 2.0
NAP-200-007
Sheet 31/55
Termination of Cables on MDF
(9) Paging Equipment
show an example of the cross connection for a customer-owned paging
equipment.
Requirement for Paging Equipment
•
Input Impedance
: 600 ohm
•
Control Method
: Start - Ground Start
Note
: Stop - Ground Off (Open)
Note:
The current capacity of relay contact (PN-DK00 card) is 0.125 A.
(a) Outline of the Connection (see
Figure 007-23 Paging Equipment Connection Outline
G
G
For Control
MDF
G
PBX
PN-4COT Card
PN-DK00 Card
PZ-PW86/PZ-PW112 Card
For Amplifier Input
Paging Equipment