NDA-24219
CHAPTER
3
Page 49
Revision 2.0
NAP-200-006
Sheet 2/2
Cable Running to MDF
2.
CABLE RUNNING TO EXTERNAL MDF
(1) Bring the MDF cable up to the Main Equipment through the cable hole(s) of the bottom cover.
(2) Connect the champ connector of each MDF cable to an LTC connector located on a PIM using the screws
provided, as shown in
(3) Pare the sheath of each MDF cable and secure the shield to the bottom of the PIM using tie wraps, as shown
Figure 006-2 Cable Running to External MDF
LTC CONNECTOR
CHAMP CONNECTOR
FRONT
TO MDF
PIM
PBX
PIM
MDF
CABLE
TIE WRAP
25-30 mm
(1.0-1.2 inch)
SHIELD