![background image](http://html.mh-extra.com/html/nec/neax-1000-ivs/neax-1000-ivs_system-manual_251362115.webp)
NDA-24219
CHAPTER
3
Page 101
Revision 2.0
NAP-200-007
Sheet 52/55
Termination of Cables on MDF
(b) MDF Cross Connection with AC Adapter Power Option (see
Figure 007-40 MDF Cross Connection with AC Adapter Power Option
26
Bx
1
Ax
LTC0 (J)
1
Ax
26
Bx
(P)
LEN0000
MDF
LEN0000
Ax
Bx
Ax
Bx
PN-8DLC
PIM0
1
26
1
2
3
4
5
6
MODULAR
TERMINAL
-24 AC Adapter
to Commercial
AC Outlet
SN716 DESKCON