(3) Module ID (ID LED)
Module ID LED is used for identifying the server that requires maintenance among servers mounted on a
rack.
LED indication
Description
Action
On (green)
UID switch is pressed.
–
Blinking (green)
The server is receiving an identification request sent
by remote.
–
Off –
–
(4) CPU (CPU FAULT LED)
The LED lights amber when the CPU part of CPU/IO modules fails.
(5) MEM NUMBER (Memory slot error LED)
The LED lights amber when failure occurs on the memory slot 0 of CPU/IO module.
Memory slots with errors can be identified by illumination status of the following (5)-1 to (5)-4.
Status of memory slot error LED
Description
Action
(5)-1
(MSB)
(5)-2
(5)-3
(5)-4
(LSB)
–
–
–
–
Operating normally
–
–
–
–
○
Error at memory slot 1
Contact your sales representative.
–
–
○
–
Error at memory slot 2
Contact your sales representative.
–
–
○
○
Error at memory slot 3
Contact your sales representative.
–
○
–
–
Error at memory slot 4
Contact your sales representative.
–
○
–
○
Error at memory slot 5
Contact your sales representative.
–
○
○
–
Error at memory slot 6
Contact your sales representative.
–
○
○
○
Error at memory slot 7
Contact your sales representative.
○
–
–
–
Error at memory slot 8
Contact your sales representative.
–
–
–
●
Error at memory slot 9
Contact your sales representative.
–
–
●
–
Error at memory slot 10
Contact your sales representative.
–
–
●
●
Error at memory slot 11
Contact your sales representative.
–
●
–
–
Error at memory slot 12
Contact your sales representative.
–
●
–
●
Error at memory slot 13
Contact your sales representative.
–
●
●
–
Error at memory slot 14
Contact your sales representative.
–
●
●
●
Error at memory slot 15
Contact your sales representative.
●
–
–
–
Error at memory slot 16
Contact your sales representative.
●
●
●
●
Error at unknown memory slot, or
memory is not installed.
Contact your sales representative.
○
:
LED is lit.
●
:
LED is blinking.
–:
LED is unlit.