4. Maintenance of Express5800/ft series
Express5800/R310e-E4, R320e-E4, R320e-M4, R310f-E4, R320f-E4, R320f-M4 Maintenance Guide (Windows)
39
Chapter 1 Maintenance
6. When you click
OK
on confirmation dialog box, the firmware update starts.
Tips
The update result can be checked by
Status Information
of
General
in target
component ("Firmware update complete" is displayed). In addition, the result of the
update is reported by the ft server as an alert.
It takes about 15 minutes until the update of either of CPU module is completed.
When the firmware update is completed, check that the firmware revision is modified as you expect.
7. When BIOS update completes, choose
Update
, and then click the
Execute
button of
Jump Switch
.
( "Jump Switch" can be carried out to module of "Power supply stopped". )
8. When you click
OK
on confirmation dialog box, the CPU module of which BIOS has been updated starts,
and the other CPU module stops.
9. Click the
Execute
button of
Firmware Update
on
Update
screen of the CPU module in halt status.