8. Troubleshooting
Express5800/R310e-E4, R320e-E4, R320e-M4, R310f-E4, R320f-E4, R320f-M4 Maintenance Guide (Windows)
101
Chapter 1 Maintenance
Device name
Device ID
CPU1 on CPU module 1
1/21
CPU2 on CPU module 1
1/22
PCI module 0
10
PCI slot 1 on PCI module 0
10/1
PCI slot 2 on PCI module 0
10/2
PCI slot 3 on PCI module 0
10/3
PCI slot 4 on PCI module 0
10/4
SCSI adaptor on PCI module 0
10/5
Ethernet board 1 on PCI module 0
10/6
Ethernet board 2 on PCI module 0
10/12
PCI module 1
11
PCI slot 1 on PCI module 1
11/1
PCI slot 2 on PCI module 1
11/2
PCI slot 3 on PCI module 1
11/3
PCI slot 4 on PCI module 1
11/4
SCSI adaptor on PCI module 1
11/5
Ethernet board 1 on PCI module 1
11/6
Ethernet board 2 on PCI module 1
11/12
SCSI enclosure 0
10/40
SCSI slot 1 on SCSI enclosure 0
10/40/1
SCSI slot 2 on SCSI enclosure 0
10/40/2
SCSI slot 3 on SCSI enclosure 0
10/40/3
SCSI slot 4 on SCSI enclosure 0
10/40/4
SCSI slot 5 on SCSI enclosure 0
10/40/5
SCSI slot 6 on SCSI enclosure 0
10/40/6
SCSI slot 7 on SCSI enclosure 0
10/40/7
SCSI slot 8 on SCSI enclosure 0
10/40/8
SCSI enclosure 1
11/40
SCSI slot 1 on SCSI enclosure 1
11/40/1
SCSI slot 2 on SCSI enclosure 1
11/40/2
SCSI slot 3 on SCSI enclosure 1
11/40/3
SCSI slot 4 on SCSI enclosure 1
11/40/4
SCSI slot 5 on SCSI enclosure 1
11/40/5
SCSI slot 6 on SCSI enclosure 1
11/40/6
SCSI slot 7 on SCSI enclosure 1
11/40/7
SCSI slot 8 on SCSI enclosure 1
11/40/8
* "SCSI" includes SAS.
* For R310e-E4, R320e-E4, R310f-E4 and R320f-E4, PCI slot 3 and PCI slot 4 do not exist on the PCI module.
LAN Monitoring Threshold
Because the ft server detects hardware faults on the network in the driver level, NEC ESMPRO
Agent does not monitor line faults. Thus, the setting of
Line fault occurrence rate
on
LAN
tab
of
NEC ESMPRO Agent properties
is not used.
Temperature/voltage error occurs on the CPU/PCI modules
At the time when a temperature or voltage error occurs on CPU/PCI module (CPU/IO module),
necessary actions will differ depending on their status as shown below. You can check the
status of each module from the
Information of server state/constitution
of NEC ESMPRO
Manager or ft server utility.
Status
Operation
Duplex
Stop the failed CPU/PCI module (CPU/IO module).
Other than Duplex, Empty
Shut down the system.
Содержание Express5800/R310e-E4