![background image](http://html.mh-extra.com/html/nec/express5800-180ra-7/express5800-180ra-7_user-manual_251232186.webp)
5-20
Problem Solving
Table 5-1. Power On LCD Error Messages (continued)
Error Message
Description
Action
L2#8 Volt Alm 00
Voltage warning:
The CPU #8 L2 cache voltage is too low.
L2#8 Volt Alm 02
Voltage alarm:
The CPU #8 L2 cache voltage is too low.
L2#8 Volt Alm 07
Voltage warning:
The CPU #8 L2 cache voltage is too high.
L2#8 Volt Alm 09
Voltage alarm:
The CPU #8 L2 cache voltage is too high.
Check if the VRM for CPU #8 is
mounted correctly. If the same
error still occurs when the VRM is
mounted correctly, call your service
representative.
Memory C-Err nn
Correctable system memory error nn:
Number 01 to 16
Memory U-Err nn
Uncorrectable system memory error nn:
Number 01 to 18
Check if the memory board or
memory backboard is mounted
correctly. Call your service
representative, and replace the
corresponding DIMM board.
OS shutdown Alm
Operating system shutdown alarm
An alarm occurred at shutdown of
the operating system. Call your
service representative.
PCI Bus PERR nn
PCI bus #nn parity error nn:
Number 01 to 03 indicating the bus number
PCI Bus SERR nn
PCI bus #nn system error nn:
Number 01 to 03 indicating the bus number
Check if the board in the
corresponding PCI bus slot is
mounted correctly. If the same
error still occurs when the board is
mounted correctly, call your service
representative.
PCIHotPlug Err 1
PCI bus #1 hot plug controller alarm
PCIHotPlug Err 2
PCI bus #2 hot plug controller alarm
PCIHotPlug Err 3
PCI bus #3 hot plug controller alarm
Check if the board in the
corresponding PCI bus slot is
mounted correctly and if the slot
tab is locked correctly. If the same
error still occurs when the board is
mounted and locked correctly, call
your service representative
Power Unit Alm 01
Power supply unit #1 alarm
Power Unit Alm 02
Power supply unit #2 alarm
Power Unit Alm 03
Power supply unit #3 alarm
Call your service representative,
and replace the faulty power
supply unit.
PredictiveAlm 01
Fan alarm of power supply unit #1
Clean the rear grill of power supply
unit #1. If the same error still
occurs, call your service
representative.
PredictiveAlm 02
Fan alarm of power supply unit #2
Clean the rear grill of power supply
unit #2. If the same error still
occurs, call your service
representative.
PredictiveAlm 03
Fan alarm of power supply unit #3
Clean the rear grill of power supply
unit #3. If the same error still
occurs, call your service
representative.
Содержание Express5800/180Ra-7
Страница 1: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Страница 2: ...xxx ...
Страница 3: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Страница 10: ...viii Contents ...
Страница 94: ...3 28 Configuring Your System ...
Страница 134: ...4 40 Upgrading Your System A B C Figure 4 43 Recabling the SCSI Interface Cable ...
Страница 166: ...4 72 Upgrading Your System ...
Страница 206: ...5 40 Problem Solving ...
Страница 207: ...A Specifications Basic System Unit BSU Disk Expansion Unit DEU ...
Страница 212: ...A 6 Specifications ...
Страница 218: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Страница 229: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Страница 232: ...D 4 ROMPilot BIOS Error Codes ...
Страница 242: ...10 Glossary ...
Страница 246: ...4 Equipment Log ...
Страница 250: ...Index 4 ...
Страница 251: ...xx ...
Страница 252: ... 456 01516 000 ...