Table 5-1. Power On LCD Error Messages (continued)
Error Message
Description
Action
CPU4 Volt Alm 00
Voltage warning:
The CPU #4 voltage is too low.
CPU4 Volt Alm 02
Voltage alarm:
The CPU #4 voltage is too low.
CPU4 Volt Alm 07
Voltage warning:
The CPU #4 voltage is too high.
CPU4 Volt Alm 09
Voltage alarm:
The CPU #4 voltage is too high.
Check if the VRM for CPU #4 is
mounted correctly. If the same
error still occurs when the VRM is
mounted correctly, call your
service representative.
CPU5 Temp Alm 00
Temperature warning:
The CPU #5 temperature is too low.
CPU5 Temp Alm 02
Temperature alarm:
The CPU #5 temperature is too low.
CPU5 Temp Alm 07
Temperature warning:
The CPU #5 temperature is too high.
CPU5 Temp Alm 09
Temperature alarm:
The CPU #5 temperature is too high.
Stop the device, and check if the
device operating environment
temperature is appropriate. Also
confirm that the fans and
components are not clogged with
dust. If the system still detects an
abnormality, call your service
representative.
CPU5 Volt Alm 00
Voltage warning:
The CPU #5 voltage is too low.
CPU5 Volt Alm 02
Voltage alarm:
The CPU #5 voltage is too low.
CPU5 Volt Alm 07
Voltage warning:
The CPU #5 voltage is too high.
CPU5 Volt Alm 09
Voltage alarm:
The CPU #5 voltage is too high.
Check if the VRM for CPU #5 is
mounted correctly. If the same
error still occurs when the VRM is
mounted correctly, call your
service representative.
CPU6 Temp Alm 00
Temperature warning:
The CPU #6 temperature is too low.
CPU6 Temp Alm 02
Temperature alarm:
The CPU #6 temperature is too low.
CPU6 Temp Alm 07
Temperature warning:
The CPU #6 temperature is too high.
CPU6 Temp Alm 09
Temperature alarm:
The CPU #6 temperature is too high.
Stop the device, and check if the
device operating environment
temperature is appropriate. Also
confirm that the fans and
components are not clogged with
dust. If the system still detects an
abnormality, call your service
representative
CPU6 Volt Alm 00
Voltage warning:
The CPU #6 voltage is too low.
CPU6 Volt Alm 02
Voltage alarm:
The CPU #6 voltage is too low.
CPU6 Volt Alm 07
Voltage warning:
The CPU #6 voltage is too high.
CPU6 Volt Alm 09
Voltage alarm:
The CPU #6 voltage is too high.
Check if the VRM for CPU #6 is
mounted correctly. If the same
error still occurs when the VRM is
mounted correctly, call your
service representative.
Содержание Express5800/180Ra-7
Страница 1: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Страница 2: ...xxx ...
Страница 3: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Страница 10: ...viii Contents ...
Страница 94: ...3 28 Configuring Your System ...
Страница 134: ...4 40 Upgrading Your System A B C Figure 4 43 Recabling the SCSI Interface Cable ...
Страница 166: ...4 72 Upgrading Your System ...
Страница 206: ...5 40 Problem Solving ...
Страница 207: ...A Specifications Basic System Unit BSU Disk Expansion Unit DEU ...
Страница 212: ...A 6 Specifications ...
Страница 218: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Страница 229: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Страница 232: ...D 4 ROMPilot BIOS Error Codes ...
Страница 242: ...10 Glossary ...
Страница 246: ...4 Equipment Log ...
Страница 250: ...Index 4 ...
Страница 251: ...xx ...
Страница 252: ... 456 01516 000 ...