Table 5-1. Power On LCD Error Messages (continued)
Error Message
Description
Action
+3.3vs
Alm 07
Voltage warning:
The power 3.3 VS is too high.
+3.3vs
Alm 09
Voltage alarm:
The power 3.3 VS is too high.
+5.0v
Alm 00
Voltage warning:
The power 5 V is too low.
+5.0v
Alm 02
Voltage alarm:
The power 5 V is too low.
+5.0v
Alm 07
Voltage warning:
The power 5 V is too high.
+5.0v
Alm 09
Voltage alarm:
The power 5 V is too high.
Contact your service
representative to replace the power
supply or I/O riser card.
AC lost
Alm 01
The power plug of power supply #1 is
not connected.
AC lost
Alm 02
The power plug of power supply #2 is
not connected.
AC lost
Alm 03
The power plug of power supply #3 is
not connected.
Connect the power cord. If the
same error still occurs, call your
service representative.
AmbientTempAlm00
Temperature warning: The ambient
temperature is too low.
AmbientTempAlm02
Temperature alarm: The ambient
temperature is too low.
AmbientTempAlm07
Temperature warning: The ambient
temperature is too high.
AmbientTempAlm09
Temperature alarm: The ambient
temperature is too high.
Stop the device, and check if the
device operating environment
temperature is appropriate. Also
confirm that the fans and
components are not clogged with
dust. If the system still detects an
abnormality, call your service
representative.
Chipset Err xxxx
System error
An error has been detected on the
baseboard or system I/O board.
Check if both boards are mounted
correctly. If the same error still
occurs when the boards are
mounted correctly, call your service
representative.
Cover Open
The top cover or side cover is open.
Close the top cover or side cover
firmly. If the same error still
occurs, call your service
representative.
CPU1 Temp Alm 00
Temperature warning:
The CPU #1 temperature is too low.
CPU1 Temp Alm 02
Temperature alarm:
The CPU #1 temperature is too low.
CPU1 Temp Alm 07
Temperature warning:
The CPU #1 temperature is too high.
CPU1 Temp Alm 09
Temperature alarm:
The CPU #1 temperature is too high.
Stop the device, and check if the
device operating environment
temperature is appropriate. Also
confirm that the fans and
components are not clogged with
dust. If the system still detects an
abnormality, call your service
representative.
Содержание Express5800/180Ra-7
Страница 1: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Страница 2: ...xxx ...
Страница 3: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Страница 10: ...viii Contents ...
Страница 94: ...3 28 Configuring Your System ...
Страница 134: ...4 40 Upgrading Your System A B C Figure 4 43 Recabling the SCSI Interface Cable ...
Страница 166: ...4 72 Upgrading Your System ...
Страница 206: ...5 40 Problem Solving ...
Страница 207: ...A Specifications Basic System Unit BSU Disk Expansion Unit DEU ...
Страница 212: ...A 6 Specifications ...
Страница 218: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Страница 229: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Страница 232: ...D 4 ROMPilot BIOS Error Codes ...
Страница 242: ...10 Glossary ...
Страница 246: ...4 Equipment Log ...
Страница 250: ...Index 4 ...
Страница 251: ...xx ...
Страница 252: ... 456 01516 000 ...