![background image](http://html.mh-extra.com/html/nec/express5800-180ra-7/express5800-180ra-7_user-manual_251232183.webp)
Problem Solving 5-17
Table 5-1. Power On LCD Error Messages (continued)
Error Message
Description
Action
CPU7 Temp Alm 00
Temperature warning:
The CPU #7 temperature is too low.
CPU7 Temp Alm 02
Temperature alarm:
The CPU #7 temperature is too low.
CPU7 Temp Alm 07
Temperature warning:
The CPU #7 temperature is too high.
CPU7 Temp Alm 09
Temperature alarm:
The CPU #7 temperature is too high.
Stop the device, and check if the
device operating environment
temperature is appropriate. Also
confirm that the fans and
components are not clogged with
dust. If the system still detects an
abnormality, call your service
representative
CPU7 Volt Alm 00
Voltage warning:
The CPU #7 voltage is too low.
CPU7 Volt Alm 02
Voltage alarm:
The CPU #7 voltage is too low.
CPU7 Volt Alm 07
Voltage warning:
The CPU #7 voltage is too high.
CPU7 Volt Alm 09
Voltage alarm:
The CPU #7 voltage is too high.
Check if the VRM for CPU #7 is
mounted correctly. If the same
error still occurs when the VRM is
mounted correctly, call your
service representative.
CPU8 Temp Alm 00
Temperature warning:
The CPU #8 temperature is too low.
CPU8 Temp Alm 02
Temperature alarm:
The CPU #8 temperature is too low.
CPU8 Temp Alm 07
Temperature warning:
The CPU #8 temperature is too high.
CPU8 Temp Alm 09
Temperature alarm:
The CPU #8 temperature is too high.
Stop the device, and check if the
device operating environment
temperature is appropriate. Also
confirm that the fans and
components are not clogged with
dust. If the system still detects an
abnormality, call your service
representative
CPU8 Volt Alm 00
Voltage warning:
The CPU #8 voltage is too low.
CPU8 Volt Alm 02
Voltage alarm:
The CPU #8 voltage is too low.
CPU8 Volt Alm 07
Voltage warning:
The CPU #8 voltage is too high.
CPU8 Volt Alm 09
Voltage alarm:
The CPU #8 voltage is too high.
Check if the VRM for CPU #8 is
mounted correctly. If the same
error still occurs when the VRM is
mounted correctly, call your
service representative.
CPU IERR 01
CPU #1 error
CPU IERR 02
CPU #2 error
CPU IERR 03
CPU #3 error
CPU IERR 04
CPU #4 error
CPU IERR 05
CPU #5 error
CPU IERR 06
CPU #6 error
CPU IERR 07
CPU #7 error
CPU IERR 08
CPU #8 error
Check if the CPU and CPU
termination board are mounted
correctly. If the same error still
occurs when they are mounted
correctly, call your service
representative.
Содержание Express5800/180Ra-7
Страница 1: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Страница 2: ...xxx ...
Страница 3: ... U s e r s G u i d e EXPRESS5800 180Ra 7 ...
Страница 10: ...viii Contents ...
Страница 94: ...3 28 Configuring Your System ...
Страница 134: ...4 40 Upgrading Your System A B C Figure 4 43 Recabling the SCSI Interface Cable ...
Страница 166: ...4 72 Upgrading Your System ...
Страница 206: ...5 40 Problem Solving ...
Страница 207: ...A Specifications Basic System Unit BSU Disk Expansion Unit DEU ...
Страница 212: ...A 6 Specifications ...
Страница 218: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Страница 229: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Страница 232: ...D 4 ROMPilot BIOS Error Codes ...
Страница 242: ...10 Glossary ...
Страница 246: ...4 Equipment Log ...
Страница 250: ...Index 4 ...
Страница 251: ...xx ...
Страница 252: ... 456 01516 000 ...