background image

 

H3C UniServer R4300 G5 Server 

Processor Installation Quick Start 

 

 

 
 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
New H3C Technologies Co., Ltd.  
http://www.h3c.com 
 
Document version: 6W100-20220118

 

 

Summary of Contents for UniServer R4300 G5

Page 1: ...H3C UniServer R4300 G5 Server Processor Installation Quick Start New H3C Technologies Co Ltd http www h3c com Document version 6W100 20220118 ...

Page 2: ...respective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accurate but they are presented without warranty of any kind express or implied H3C shall not be liable for technical or editorial errors or omissions contained herein Environmental protection This produc...

Page 3: ...ired syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional syntax choices separated by vertical bars from which you select one or none x y Asterisk marked braces enclose a set of required syntax choices separated by vertical bars from which you select a minimum of one x y Asterisk marked square brackets enclose optional syntax choices sep...

Page 4: ... switch such as a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a unified wired WLAN switch Represents an access point Wireless terminator unit Wireless terminator Represents a mesh access point Represents omnidirectional signals Represents directional ...

Page 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments ...

Page 6: ...i Content Overview 1 Processor kit 1 Preparing for installation 1 Installing the processor 3 Installing DIMMs 8 Starting the server 9 ...

Page 7: ...d personnel and professional server engineers can install a processor When installing or removing the processors wear a reliably grounded ESD wrist strap and a pair of ESD gloves to prevent ESD damage to the processors When installing or removing other components except for the processors wear a reliably grounded ESD wrist strap to prevent ESD damage To prepare the server for processor installatio...

Page 8: ...s panel 6 Remove the chassis air baffle As shown in Figure1 2 open the hooks marked by blue trapezoids on the chassis air baffle and then lift the air baffle up to remove it from the chassis Figure1 2 Removing the chassis air baffle ...

Page 9: ...ON When you remove the protective cover from the heatsink be careful not to touch the thermal grease on the heatsink Figure1 3 Removing the protective cover 2 Install the retaining bracket onto the heatsink a As shown in Figure1 4 align the alignment triangle on the retaining bracket with the cut off corner of the heatsink b Lower the bracket vertically down on the heatsink until the four corners ...

Page 10: ... to a processor always hold the processor by the edges Never touch the gold contacts on the processor bottom a Tilt the processor align the small triangle on the processor with the alignment triangle in the retaining bracket and insert one edge of the processor into the retaining bracket Place two thumbs against the heatsink press the other end of the processor and lower the processor ...

Page 11: ...e the processor socket cover CAUTION Be careful not to touch the pins on the processor socket when you wear ESD gloves to remove the processor socket cover The pins on the processor socket are very fragile Never touch the pins Any damage to them might require system board replacement Keep the pins on the processor socket clean Make sure the socket is free from dust and any other debris ...

Page 12: ...eatsink onto the server a Align the alignment triangle on the retaining bracket with the cut off corner of the processor socket and the pin holes in the heatsink with the guide pins on the processor socket Lower down the heatsink on the processor socket See Figure1 9 CAUTION To avoid damages to the heatsink hold the heatsink in the correct way as shown in Figure1 10 Figure1 9 Attaching the heatsin...

Page 13: ... the heatsink in place Figure1 11 Locking the heatsink c Use a T30 Torx screwdriver to fasten the four captive screws in a diagonal sequence on the heatsink CAUTION Adjust the torque value to 0 9 Nm 8 in lbs to avoid poor contact of the processor or damage to the pins on the processor socket ...

Page 14: ...alling DIMMs After you install a new processor install DIMMs for it For the DIMM installation guidelines see the server user guide To install a DIMM 1 Open the retaining clips of the DIMM slot Figure1 13 Opening the retaining clips of the DIMM slot ...

Page 15: ...u cannot insert the DIMM into the slot easily the installation might be wrong Re orient the DIMM and then insert it into the slot again Figure1 14 Installing a DIMM Starting the server 1 Install the chassis air baffle on the server Align the notches on the air baffle with the pins on the chassis side panels and then place the air baffle into the chassis Figure1 15 Installing the chassis air baffle...

Page 16: ...the server front b Close the locking lever The access panel will automatically slide toward the server front to secure itself into place c Optional Lock the locking lever Use a Phillips screwdriver to turn the screw on the lever 90 degree clockwise Figure1 16 Installing the access panel 3 Install the server into the rack 4 Connect power cords for the server 5 Power on the server ...

Reviews: