138
-
8.5 Operation of Battery and DIMM for Onboard RAID
8.5.1
Error Indication by POST
The information on onboard RAID is normally indicated by POST as follows:
LSI MegaRAID BIOS Version XXX (Build XXX XX XXXX)
Copyright(C) 2005 LSI Logic Corp.
HA-X (Bus XX Dev XX) MegaRAIS SCSI 320-2E
Standard FW XXXX DRAM = 256MB (SDRAM)
Battery module is present on adapter
Channel-0 ID-14 -- XXX XXXXX
Channel-1 ID-14 -- XXX XXXXX
X Logical Drive(s) found on the host adapter.
X Logical Drive(s) handled by BIOS
Press <Ctrl><M> or <Enter> to Run Config Utility
Or Press <Ctrl><H> for WebBIOS
The actions taken against error messages other than above are as follows:
Error messages about the battery
The battery for onboard RAID may be defected. Replace the battery for onboard RAID
following the description in Subsection 4.10.11.
If the similar message appears after the replacement, replace the I/O Board.
Error messages about the memory
A DIMM for onboard RAID may be defected. Replace the defected DIMM for onboard
RAID following the description in Subsection 4.10.11.
If the similar message appears after the replacement, replace the I/O Board.
Error messages about the RAID key
The RAID key, a device on the I/O Board, may be defected. Replace the I/O Board.
Error messages about the HDD
An HDD may be defected. Check the LEDs on the HDDs to replace the defected HDD.
8.5.2
Error Messages by Windows Event Log
When Power Console Plus is installed in the Server, the onboard RAID log can be checked by the
event log (application) of the Event Viewer. Isolate the suspicious device depending on the error
type to replace the device.
Содержание EXPRESS5800/140He
Страница 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Страница 2: ...This page is intentionally left blank ...
Страница 4: ...This page is intentionally left blank ...
Страница 38: ... 22 Internal View 140Rd 4 1 Fan bay 2 Hot plug PCI slot 3 Non hot plug PCI slot 4 Power supply cage 1 2 3 4 ...
Страница 39: ... 23 Internal View 140He 1 Power supply cage 2 Non hot plug PCI slot 3 Hot plug PCI slot 4 Fan bay 1 2 3 4 ...
Страница 41: ... 25 140He same as 140Rd 4 plus the following 3 5 inch disk bay Optional hard disk bays 8 5 25 inch disk bays ...
Страница 73: ... 57 Processor board error lamp Processor VRM error lamps Processor board error lamp REAR FRONT ...
Страница 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Страница 153: ... 137 voltage drop and the system is restarted This is not an error ...
Страница 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Страница 163: ... 147 ...
Страница 181: ... 165 12 3 Block Diagram ...
Страница 182: ... 166 This page is intentionally left blank ...
Страница 183: ... 167 This page is intentionally left blank ...
Страница 184: ... 168 ...