![NEC EXPRESS5800/140He Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/nec/express5800-140he/express5800-140he_service-manual_251225089.webp)
-
73
-
4.9.4
Replacement of Processor Board, Processor, Heat Sink
or VRM
The figure shows the Server mounted on the 140Rd-4 chassis. The Server on the 140He chassis is
different only in that it is mounted longitudinally. The replacement procedure is the same for both
servers except when specified otherwise.
1.
Release the lock on the front bezel by using the security key to remove the front bezel.
2.
Remove the memory slot cover on the front of the Server (by removing the two captive
screws).
3.
Remove the processor slot cover (by removing 2 screws.)
4.
Release the lock and open the left and right ejectors together.
Содержание EXPRESS5800/140He
Страница 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Страница 2: ...This page is intentionally left blank ...
Страница 4: ...This page is intentionally left blank ...
Страница 38: ... 22 Internal View 140Rd 4 1 Fan bay 2 Hot plug PCI slot 3 Non hot plug PCI slot 4 Power supply cage 1 2 3 4 ...
Страница 39: ... 23 Internal View 140He 1 Power supply cage 2 Non hot plug PCI slot 3 Hot plug PCI slot 4 Fan bay 1 2 3 4 ...
Страница 41: ... 25 140He same as 140Rd 4 plus the following 3 5 inch disk bay Optional hard disk bays 8 5 25 inch disk bays ...
Страница 73: ... 57 Processor board error lamp Processor VRM error lamps Processor board error lamp REAR FRONT ...
Страница 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Страница 153: ... 137 voltage drop and the system is restarted This is not an error ...
Страница 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Страница 163: ... 147 ...
Страница 181: ... 165 12 3 Block Diagram ...
Страница 182: ... 166 This page is intentionally left blank ...
Страница 183: ... 167 This page is intentionally left blank ...
Страница 184: ... 168 ...