134
-
On-screen message
Action
8132
Mismatch DIMM detected in DIMM
group #3
8133
Mismatch DIMM detected in DIMM
group #4
8134
Mismatch DIMM detected in DIMM
group #5
8135
Mismatch DIMM detected in DIMM
group #6
8136
Mismatch DIMM detected in DIMM
group #7
8137
Mismatch DIMM detected in DIMM
group #8
8140
DIMM group #1 with error is enabled
8141
DIMM group #2 with error is enabled
8142
DIMM group #3 with error is enabled
8143
DIMM group #4 with error is enabled
8144
DIMM group #5 with error is enabled
8145
DIMM group #6 with error is enabled
8146
DIMM group #7 with error is enabled
8147
DIMM group #8 with error is enabled
Replace the DIMMs in relevant group.
8150
NVRAM cleared by Jumper
8151
Password Cleared by Jumper
Set the jumper switch as before after
turning off the power.
8160
Mismatch processor Speed detected
on Processor 1
8161
Mismatch processor Speed detected
on Processor 2
8162
Mismatch processor Speed detected
on Processor 3
8163
Mismatch processor Speed detected
on Processor 4
Check the frequency of CPU. Replace the
CPU of rated frequency.
8170
Processor 1 not operating at intended
frequency
8171
Processor 2 not operating at intended
frequency
8172
Processor 3 not operating at intended
frequency
8173
Processor 4 not operating at intended
frequency
Check the frequency of CPU. Replace the
CPU of rated frequency.
817F
All Processor not operating at intended
frequency
Check the frequency of CPU. Replace the
CPU of rated frequency.
8200
Online Spare Memory was not ready
Use DIMMs of the same type.
The dedicated maintenance parts are
specified for online spare memory.
8201
Mirroring Memory was not ready.
Use DIMMs of the same type.
The dedicated maintenance parts are
specified for online spare memory.
8202
Memory RAID was not ready
Check the memory capacity and type for all
the DIMMs. Check also if they are correctly
installed.
Содержание EXPRESS5800/140He
Страница 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Страница 2: ...This page is intentionally left blank ...
Страница 4: ...This page is intentionally left blank ...
Страница 38: ... 22 Internal View 140Rd 4 1 Fan bay 2 Hot plug PCI slot 3 Non hot plug PCI slot 4 Power supply cage 1 2 3 4 ...
Страница 39: ... 23 Internal View 140He 1 Power supply cage 2 Non hot plug PCI slot 3 Hot plug PCI slot 4 Fan bay 1 2 3 4 ...
Страница 41: ... 25 140He same as 140Rd 4 plus the following 3 5 inch disk bay Optional hard disk bays 8 5 25 inch disk bays ...
Страница 73: ... 57 Processor board error lamp Processor VRM error lamps Processor board error lamp REAR FRONT ...
Страница 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Страница 153: ... 137 voltage drop and the system is restarted This is not an error ...
Страница 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Страница 163: ... 147 ...
Страница 181: ... 165 12 3 Block Diagram ...
Страница 182: ... 166 This page is intentionally left blank ...
Страница 183: ... 167 This page is intentionally left blank ...
Страница 184: ... 168 ...