Setting Up the System 2-21
Status LED Indicator Descriptions
Table 2-1 lists the system status LED indicators along with a description of each
LED indicator. Table 2-2 lists the disk drive status LED panel indicators along
with a description of each LED indicator. Refer to Figures 2-18 for the location
of the LED indicators listed in Tables 2-1 and 2-2.
Table 2-1. System Status LED Indicators
LED
Status
Description
Response
Off
Power interrupted to
the system
Check AC connection; check system
power supply.
Green
Power applied to
system.
None required (normal)
Power/Sleep Status
(See Figure 2-18, E)
Amber
**System power saving
(sleep) mode.
Press Power/Sleep button to enter
Sleep mode and to return to Normal
mode.
Off (Power
LED is also
off)
Power is turned off
Turn power on.
Currently executing
POST
Wait for POST to complete.
CPU Error occurred
Detected uncorrectable
memory error
Detected an SMI
timeout
PCI system error
occurred
Turn the system off and then on again.
In the event an error message is
displayed during the subsequent
POST...write the error message down
and contact your field service
representative.
Off
Dump switch was
pressed
Wait for the memory dump to be
completed.
Green
Normal operation
None required. (normal)
Operating with either
CPU or memory
disabled.
CPU or memory error. Verify which
CPU or memory bank was disabled by
entering the F2 BIOS Setup menu and
replace the component as soon as
possible.
Blinking
Green
Multiple correctable
memory errors were
detected
Multiple single-bit ECC errors detected.
Contact your field service
representative to arrange the
replacement of memory.
Amber
(Power LED
is off)
Detected missing CPU
or missing CPU
terminator
Confirm that all CPU's and CPU
terminators are inserted firmly and
correctly.
Amber
Detected an abnormal
thermal/voltage
condition
Clean the internal fans. Check that no
cables are obstructing the internal air
flow. If the error persists, contact your
field service representative.
Detected an abnormal
voltage level
Detected a failed fan
Status LED (See Figure
2-18, F)
Blinking
Amber
(Continued
on next
page)
Detected a
thermal/voltage
warning
Clean the internal fans. Check that no
cables are obstructing the internal air
flow. If the error persists, contact your
field service representative.
Содержание Express5800/120Rc-2
Страница 1: ... S e r v i c e G u i d e EXPRESS5800 120Rc 2 ...
Страница 2: ...xxx ...
Страница 3: ... S e r v i c e G u i d e EXPRESS5800 120Rc 2 ...
Страница 43: ...Setting Up the System 2 15 Figure 2 13 Attaching Cables to the Cable Arm Assembly ...
Страница 52: ...2 24 Setting Up the System 2 1 1 2 Figure 2 20 Making Connections ...
Страница 76: ......
Страница 124: ...4 48 Disassembly and Reassembly A Figure 4 56 Installing the PCI I O Board Figure 4 57 Securing an PCI I O Board ...
Страница 158: ...5 22 Problem Solving ...
Страница 169: ...B Technical Specifications Server Unit ...
Страница 172: ......
Страница 173: ...C Connectors Overview External Device Connector Pinout Information ...
Страница 188: ......
Страница 193: ...xx ...
Страница 194: ... 456 01554 000 ...