4-20
Upgrading Your System
!
The onboard SCSI controller supports Low Voltage Differential (LVD)
and Ultra-160/M drives. The hard disk SCSI address assignment is:
Bay
Device
SCSI ID Address
1
First 1.6 inch Hard Disk (Bottom)
0
2
Second 1.6 inch Hard Disk
1
3
Third 1.6 inch Hard Disk
2
4
Fourth 1.0 inch Hard Disk
3
5
Fifth 1.0 inch Hard Disk
4
6
Sixth 1.0 inch Hard Disk
5
7
Seventh 1.0 inch Hard Disk (Top)
6
Installing or Swapping a Hard Disk Drive in a Hot-swap Bay
This procedure describes installing a new drive or swapping out a faulty drive
from one of the seven hot-swap SCSI disk drive bays. The 3 1/2-inch SCSI
drives must use the industry standard 80-pin Single Connector Attachment
(SCA) connector. Each drive must be installed in a drive carrier.
Note:
To order a disk with a carrier, contact your sales
representative or dealer.
!
If installing new drives, follow an installation scheme starting with the
bottom drive. Fill the bays bottom to top.
!
If an individual SCSI drive fault LED (yellow light) is on steadily, this
indicates that the drive has been flagged as faulty by the RAID controller.
Follow the procedure described in this section to remove the faulty drive
and swap in a good one.
Note:
ESD can damage disk drives, boards, and other
parts. This system can withstand normal levels of
environmental ESD while you are hot-swapping SCSI hard
drives. However, we recommend that you do all procedures
in this chapter only at an ESD workstation or provide some
ESD protection by wearing an antistatic wrist strap attached
to chassis ground
any unpainted metal surface
on your
system when handling parts.
!
CAUTION
D
rive manufacturers caution against moving a disk drive
that is still spinning because of possible damage to the drive.
Содержание Express5800/120Mc2 series
Страница 1: ... U s e r s G u i d e EXPRESS5800 120Mc2 ...
Страница 2: ...xxx ...
Страница 3: ... U s e r s G u i d e EXPRESS5800 120Mc2 ...
Страница 50: ...2 18 Setting Up the System ...
Страница 106: ...4 34 Upgrading Your System Plugging in the AC Power Cords ...
Страница 125: ...A System Cabling System Cabling Before You Begin Static Precautions Standard Configuration RAID Configuration ...
Страница 129: ...System Cabling A 5 A Ultra 160 M SCSI cable 68 pins B IDE cable 40 pins Standard System Cable Routing ...
Страница 132: ...A 8 System Cabling A Ultra 160 M SCSI cable 68 pins B IDE cable 40 pins RAID System Cable Routing ...
Страница 154: ...B 22 Management Workstation Application ...
Страница 155: ...C System Status Hardware Support Information ...
Страница 166: ...10 Glossary ...
Страница 171: ...xx ...
Страница 172: ... 456 01524 000 ...