Troubleshooting 7-5
STATUS LED
Indication
Color
State
Suspected
module
Explanation Procedure
Cor0 +5.0vAlm
09
Amber
Lit
PCI module #1
Fatal
5
-V power voltage alarm
(upper limit)
Cor0 +5.0vsAlm
00
Amber Blink PCI module #1
5
-V power voltage alarm
(lower limit)
Cor0 +5.0vsAlm
02
Amber
Lit PCI module #1
Fatal
5
-V power voltage alarm
(lower limit)
Cor0 +5.0vsAlm
07
Amber Blink PCI module #1
5
-V power voltage alarm
(upper limit)
Cor0 +5.0vsAlm
09
Amber
Lit
PCI module #1
Fatal
5
-V power voltage alarm
(upper limit)
Cor0 -12vAlm 00
Amber Blink PCI module #1
-12-V power voltage alarm
(lower limit)
Cor0 -12vAlm 02
Amber
Lit
PCI module #1
Fatal -12-V power voltage
alarm (lower limit)
Cor0 -12vAlm 07
Amber Blink PCI module #1
-12-V power voltage alarm
(upper limit)
Cor0 -12vAlm 09
Amber
Lit
PCI module #1
Fatal -12-V power voltage
alarm (upper limit)
Cor0 Bus PERR
01
Green
Blink PCI module #1
PCI bus parity error
Cor0 Bus SERR
01
Green
Blink PCI module #1
Fatal PCI bus error
Cor0 CLK Alm 00
Amber Blink CLOCK
board
Clock
alarm (lower limit)
Cor0 CLK Alm 02
Amber
Lit CLOCK
board
Fatal Clock
alarm (lower
limit)
Cor0 CLK Alm 07
Amber Blink CLOCK
board
Clock
alarm (upper limit)
Cor0 CLK Alm 09
Amber
Lit CLOCK
board
Fatal Clock
alarm (upper
limit)
Contact your sales agent.
Cor0 FAN Alm 01
Amber Blink PCI module #1
Cooling fan1 alarm
Cor0 FAN Alm 02
Amber Blink PCI module #1
Cooling fan2 alarm
Cor0 FAN Alm 03
Amber Blink PCI module #1
Cooling fan3 alarm
Cor0 FAN Alm 04
Amber Blink PCI module #1
Cooling fan4 alarm
Cor0 FAN Alm 05
Amber Blink PCI module #1
Cooling fan5 alarm
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.
Cor0 offline
Green
Blink PCI module #1
PCI module logically isolated Start the PCI module by ft
sever utility or dismount
and remount that module.
If not solved by the above,
contact your sales agent.
Cor0 removed
Green
Blink PCI module #1
PCI module detached
Dismount and remount the
PCI module. If not solved
by the above, contact your
sales agent.
Cor0 Temp Alm
00
Amber Blink PCI module #1
Temperature alarm (lower
limit)
Cor0 Temp Alm
02
Amber
Lit
PCI module #1
Fatal temperature alarm
(lower limit)
Cor0 Temp Alm
07
Amber Blink PCI module #1
Temperature alarm (upper
limit)
Cor0 Temp Alm
09
Amber
Lit
PCI module #1
Fatal temperature alarm
(upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.
Содержание Express 5800/320Lc
Страница 10: ...iv This page is intentionally left blank...
Страница 20: ...1 6 Precautions for Use PCI CPU Modules PCI Module Label A CPU Module Label A Label A...
Страница 34: ...1 20 Precautions for Use This page is intentionally left blank...
Страница 50: ...2 16 General Description Front View inside Tower model Rack mount model...
Страница 94: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume...
Страница 132: ...3 52 Windows Setup and Operation This page is intentionally left blank...
Страница 256: ...5 80 Installing and Using Utilities This page is intentionally left blank...
Страница 269: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 348: ...8 38 System Upgrade 17 Use cable ties to fasten the extra length of cables Cable ties included with cabinet...
Страница 362: ...8 52 System Upgrade This page is intentionally left blank...