Troubleshooting 7-9
STATUS LED
Indication
Color
State
Suspected
module
Explanation Procedure
CPU0 +5.0vAlm
07
Amber Blink CPU module #1 5-V power voltage alarm
(upper limit)
CPU0 +5.0vAlm
09
Amber
Lit
CPU module #1 Fatal 5-V power voltage alarm
(upper limit)
CPU0 +5.0vsAlm
00
Amber Blink CPU module #1 5-V power voltage alarm
(lower limit)
CPU0 +5.0vsAlm
02
Amber
Lit
CPU module #1 Fatal 5-V power voltage alarm
(lower limit)
CPU0 +5.0vsAlm
07
Amber Blink CPU module #1 5-V power voltage alarm
(upper limit)
CPU0 +5.0vsAlm
09
Amber
Lit
CPU module #1 Fatal 5-V power voltage alarm
(upper limit)
CPU0 broken
Green Blink CPU module #1 CPU module breakdown
Contact your sales agent.
CPU0 FAN Alm 01
Amber Blink
CPU module #1
Cooling fan1 alarm
CPU0 FAN Alm 03
Amber Blink
CPU module #1
Cooling fan2 alarm
CPU0 FAN Alm 04
Amber Blink
CPU module #1
Cooling fan3 alarm
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.
CPU0 offline
Green
Blink
CPU module #1
PCI module logically isolated
Start the PCI module by ft
sever utility or dismount
and remount that module.
If not solved by the above,
contact your sales agent.
CPU0 removed
Green
Blink
CPU module #1
PCI module detached
Dismount and remount the
PCI module. If not solved
by the above, contact your
sales agent.
CPU0 Temp Alm 00
Amber Blink
CPU module #1
Temperature alarm (lower
limit)
CPU0 Temp Alm 02
Amber
Lit
CPU module #1 Fatal temperature alarm
(lower limit)
CPU0 Temp Alm 07
Amber Blink
CPU module #1
Temperature alarm (upper
limit)
CPU0 Temp Alm 09
Amber
Lit
CPU module #1
Fatal temperature alarm
(upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.
CPU0 VccpAlm 00
Amber Blink
CPU module #1
CPU operating voltage alarm
(lower limit) (VCCP)
CPU0 VccpAlm 02
Amber
Lit
CPU module #1
Fatal CPU operating voltage
alarm (lower limit) (VCCP)
CPU0 VccpAlm 07
Amber Blink
CPU module #1
CPU operating voltage alarm
(upper limit) (VCCP)
CPU0 VccpAlm 09
Amber
Lit
CPU module #1
Fatal CPU operating voltage
alarm (upper limit) (VCCP)
CPU0 Vtt Alm 00
Amber Blink
CPU module #1
1.25-V power voltage alarm
(lower limit)
CPU0 Vtt Alm 02
Amber
Lit
CPU module #1
Fatal 1.25-V power voltage
alarm (lower limit)
CPU0 Vtt Alm 07
Amber Blink
CPU module #1
1.25-V power voltage alarm
(upper limit)
CPU0 Vtt Alm 09
Amber
Lit
CPU module #1
Fatal 1.25-V power voltage
alarm (upper limit)
Contact your sales agent.
Содержание Express 5800/320Lc
Страница 10: ...iv This page is intentionally left blank...
Страница 20: ...1 6 Precautions for Use PCI CPU Modules PCI Module Label A CPU Module Label A Label A...
Страница 34: ...1 20 Precautions for Use This page is intentionally left blank...
Страница 50: ...2 16 General Description Front View inside Tower model Rack mount model...
Страница 94: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume...
Страница 132: ...3 52 Windows Setup and Operation This page is intentionally left blank...
Страница 256: ...5 80 Installing and Using Utilities This page is intentionally left blank...
Страница 269: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 348: ...8 38 System Upgrade 17 Use cable ties to fasten the extra length of cables Cable ties included with cabinet...
Страница 362: ...8 52 System Upgrade This page is intentionally left blank...