General Description 2-25
LED indications
Primary Secondary
Description Action
Detected a fatal
temperature error.
If LCD displays some error message,
refer to the error message list (see
Chapter 7).
Check if dust is accumulated on internal
fans and confirm that the fan cables are
connected firmly. If the message does
not disappear, contact your sales agent.
Amber Off
Detected a fatal voltage
error.
Contact your sales agent.
Detected a temperature
error to be warned.
If LCD displays some error message,
refer to the error message list (see
Chapter 7).
Check if dust is accumulated on internal
fans and confirm that the fan cables are
connected firmly. If the message does
not disappear, contact your sales agent.
Detected a voltage error to
be warned.
Detected a device defect.
Contact your sales agent.
Amber
(blinking
every 1
second)
Off
Detected a fan alarm.
If LCD displays some error message,
refer to the error message list (see
Chapter 7).
Check if dust is accumulated on internal
fans, and confirm that the fan cables are
connected firmly. If the message does
not disappear, contact your sales agent.
BMC is being dumped.
Wait for a while; it will go off soon.
PCI module may be
connected incorrectly.
Check if PCI module is connected
correctly. Look for loose screws.
Red Off
BMC may be out of order.
BMC firmware may need
reprogramming. Contact your sales
agent.
BMC is being dumped.
Wait for a while. After a while, the BMC
status LED on the secondary will blink.
PCI module may be
connected incorrectly.
Check if PCI module is connected
correctly. Look for loose screws.
ANY*
1
Red
BMC may be out of order.
BMC firmware may need to be
rewritten. Contact your sales agent.
ANY*
1
Red
(blinking
every 0.5
second)
Transfers data being
synchronized after a PCI
module is replaced (this is
not an error).
Do not remove either of the PCI
modules or control the AC/DC power
until the LED stops blinking.
ANY*
1
Red
(blinking
every 1
second)
The revision of BMC
firmware does not match.
Contact your sales agent.
Содержание Express 5800/320Lc
Страница 10: ...iv This page is intentionally left blank...
Страница 20: ...1 6 Precautions for Use PCI CPU Modules PCI Module Label A CPU Module Label A Label A...
Страница 34: ...1 20 Precautions for Use This page is intentionally left blank...
Страница 50: ...2 16 General Description Front View inside Tower model Rack mount model...
Страница 94: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume...
Страница 132: ...3 52 Windows Setup and Operation This page is intentionally left blank...
Страница 256: ...5 80 Installing and Using Utilities This page is intentionally left blank...
Страница 269: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 348: ...8 38 System Upgrade 17 Use cable ties to fasten the extra length of cables Cable ties included with cabinet...
Страница 362: ...8 52 System Upgrade This page is intentionally left blank...