7-34 Troubleshooting
Event Log
Perflib-related logs are recorded in the application event log when system starting:
→
When system is starting, Perflib log may be registered to the application log.
The detailed information about an event log is described on Microsoft Product
Support Services. Please check the contents.
•
[INFO] Events for Performance Monitor Extensions
http://support.microsoft.com/default.aspx?scid=kb;en-us;226494
•
Application Log Events Generated When You Start Performance Counter
Query
http://support.microsoft.com/default.aspx?scid=kb;en-us;296187
•
Event ID 2003 Warning Message Logged When Loading Performance
Counters
http://support.microsoft.com/default.aspx?scid=kb;en-us;267831
Visit the Microsoft Help and Support on regular basis where you can find other
information than the above at:
http://support.microsoft.com/default.aspx?LN=en-us
.
"The NMS Service terminated unexpectedly." is recorded in the system event log:
→
Although the following log may be recorded in the system event log when starting
the system, or after exchanging PCI modules, there is no real problem on
operation. Change of a setup with PROSet II will become invalid if NMS service
stops, but you can change a setup normally because NMS service will be
automatically started when PROSet II is started.
“Source:
Service Control Manager
Event ID:
7031
Description: The NMS service terminated unexpectedly. This has occurred 1
time(s). The following corrective action will be taken in 0
milliseconds: No action.”
iANSMiniport-related logs are recorded in the system event log:
→
Although the following log may be recorded in the system event log when starting
the system, there is no real problem on operation (In the description, “X”
represents a number).
“Source:
iANSMiniport
Event ID:
35
Description: Initializing Team #X missing adapters. Check the configuration to
verify that all the adapters are present and functioning.”
→
The logs of the source “iANSMiniport” are the logs about the duplex of the
network. The following logs may be recorded in the system event log when
starting the system (In the description, “X” represents a number).
“Source:
iANSMiniport
Event ID:
11
Description: Adapter link down: Stratus emb-82544GC Copper Gigabit Adapter.”
Содержание Express 5800/320Lc
Страница 10: ...iv This page is intentionally left blank...
Страница 20: ...1 6 Precautions for Use PCI CPU Modules PCI Module Label A CPU Module Label A Label A...
Страница 34: ...1 20 Precautions for Use This page is intentionally left blank...
Страница 50: ...2 16 General Description Front View inside Tower model Rack mount model...
Страница 94: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume...
Страница 132: ...3 52 Windows Setup and Operation This page is intentionally left blank...
Страница 256: ...5 80 Installing and Using Utilities This page is intentionally left blank...
Страница 269: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 348: ...8 38 System Upgrade 17 Use cable ties to fasten the extra length of cables Cable ties included with cabinet...
Страница 362: ...8 52 System Upgrade This page is intentionally left blank...