35
Installing the System Piping
3.6.3 Wiring Diagram - Zone Pump System
The NHB-H boilers can operate a heating system with up to 3 zones. The following is the wiring diagram for a
zone pump system with 3 zones.
Without 24VAC Connections
R
W
C
R
W
C
Boiler Pump FUSE
(250VAC_10A)
ZONE3 Pump FUSE
(250VAC_10A)
ZONE2 Pump FUSE
(250VAC_10A)
ZONE1 Pump FUSE
(250VAC_10A)
CNP1
CNP2
OUT
N
L
CON2
CON1
R
W
C
R
W
C
CNB1
CNG1
CNF1
CNK1
CNI1
(250V 3.15A)
ZONE3
ZONE2
ZONE1
DHW
CNT1
CNT2
CNT3
CNT4
SUPPLY
RETURN
OUTDOOR
DHW
TANK
CNJ1
CND1
CNV3
CNV2
CNV1
CNC3
ZONE3
LWCO
ZONE2
ZONE1
CNC4
CNC5
CNC6
CNC1
CNC2
R
W
C
R
W
C
R
W
C
R
W
C
Zone Pump 3
(max. 2.5 A)
Thermostat 3
Thermostat 2
Thermostat 1
Pump Ground
Live
OUT
OUT
OUT
OUT
IN
IN
IN
IN
Live
Live
Live
Neutral
Neutral
Neutral
Neutral
Zone Pump 2
(max. 2.5 A)
Zone Pump 1
(max. 2.5 A)
Boiler Pump
(max. 2.5 A)
Note
●
If you have a 24 V thermostat, connect it to the R & C terminals on the boiler’s PCB.
●
The C terminals are for optional connections with 24 V thermostat COMMON.