68 Setting the DIP Switches
6.2 Dip Switch 2 (Set of 8 Switches)
The DIP SW2 (Set of 8 Switches) on the circuit board configures the gas type, altitude, temperature control
modes, country, and enables or disables the space heating thermostat.
1 2 3 4 5 6
O
N
O
N
1 2
3
4
5 6 7 8
Switch
Function
Setting
Comment
1
Gas Type
Natural Gas
1-OFF
Refer to Table 1 in
Propane Gas
1-ON
2 & 3
High Altitude*
0-1,999 ft (0-609 m)
2-OFF, 3-OFF
2,000-5,399 ft (610-1,645 m)
2-ON, 3-OFF
5,400-7,699 ft (1,646-2,346 m)
2-OFF, 3-ON
7,700-10,100 ft (2,347-3,078 m)
2-ON, 3-ON
4
Input rate
compensation
Used
4-OFF
-
Unused
4-ON
-
5 & 6
Reserved
-
-
-
7
Space Heating
Thermostat
Used
7-OFF
-
Unused
7-ON
-
8
Exhaust
Temperature Control
Used
8-OFF
-
Unused
8-ON
-
* Please confirm the installation elevation by using the provided QR code to access the following website (https://www.
navieninc.com/elevation) and entering the proper zip/postal code.