99
Operating the Boiler
8. Set the DHW Call Signal.
●
DHW Thermostat
●
DHW Tank Sensor
9. Setup Summary
Once the start-up Wizard is finished, a summary
of the settings will be displayed. Press the OK
button (OK) at each summary screen until the
air purge mode is displayed. Settings made in
the start-up Wizard can be adjusted from the
Main Menu and Installer Menu as described in
Section 11.5 and 11.6.
11.3 Start-Up Wizard
The start-up wizard should run the first time the
unit is powered on. The wizard must be completed
before the boiler can be used.
1. Set the language.
●
English
●
French
2. Set the time.
●
YYYY:MM:DD:HH:MM:SS
3. Set the units to display.
●
Celsius (°C), L/M, Meter
●
Fahrenheit (°F), GPM, Feet
4. Check the gas type.
●
Natural Gas
●
Propane Gas
5. Installation Elevation Check.
Displays the altitude setting using the main DIP
switch.
6. Set the zone system.
●
Zone Pump System
●
Zone Valve System
6-1. Pump 1 Settings (When Zone System is Zone
Pump System)
●
Zone 1 Pump
●
DHW Pump
7. Set the outdoor reset ON/OFF.
●
Enable
●
Disable
7-1. Set the outdoor reset curve (Enable select).
●
Finned Tube Baseboard
●
FAN Coil
●
Cast Iron Baseboard
●
Low mass Radiant
●
High mass Radiant
●
Radiator
●
Custom
7-2. Set the outdoor high temp.
7-3. Set the outdoor low temp.
7-4. Set the WWSD temp.