90 Installing a Common Vent System
9.6 Common Vent Termination
Clearances
9.6.1 Direct Vent Application – Vertical
Installation
End
Cap
12"
(30 cm)
min.
36" (91cm) min.
Exhaust
Intake
12"
(30 cm)
min.
9.6.2 Venting Intake and Exhaust to
Different Locations
Intake
End
Cap
Exhaust
9.5 Setting up the Common Vent
System
WARNING
Electric Shock Hazard
To prevent serious injury or death:
●
ALWAYS disconnect power before servicing.
●
NEVER turn power on until the electrical wiring
installation is complete.
●
NEVER remove front cover unless power to
unit is turned off or disconnected.
Refer to the following figures when setting the
common vent type.
To view and configure the cascade settings, press
the Back button (
) and the Menu button (
)
simultaneously for 3 seconds, and then select
“4. Cascade Status and Settings”.
Rotate the Command dial (
) to switch between
the parameters or to increase/decrease setting
values. Press the Command dial (
) to select “8.
Vent Type Setting”.
Note
For more information on the vent type
settings, refer to “11.13.4 Configuring a
Содержание NHB H Series