41
Installing the System Piping
3.6.6 Wiring Diagram - the Navien Sm
The Navien Sm controller may be used with the NHB-H boilers to operate a heating system with more
than 3 zones.
When Navien boilers are used with a Navien Sm zone pump controller, an RS-485 data communication
link is established through the Ready-link connection. This allows the controller and the boiler to share
operational information and to control the zones more efficiently by minimizing unnecessary pump operation.
The communication link also provides an optimal control environment for freeze protection.
Navien
Smartzone
Zone Pump Controller
+
Navien Ready-Link Cable
R
W
C
R
W
C
CNB1
CNG1
CNF1
CNK1
CNI1
Fuse
(250V 3.15A)
ZONE3
ZONE2
ZONE1
DHW
CNT1
CNT2
CNT3
CNT4
SUPPLY
RETURN
OUTDOOR
DHW
TANK
CNJ1
CND1
CNV3
CNV2
CNV1
CNC3
ZONE3
LWCO
ZONE2
ZONE1
CNC4
CNC5
CNC6
CNC1
CNC2
R
W
C
R
W
C
R
W
C
R
W
C
Refer to the user manual that is supplied with the Navien Sm zone pump controller for details.
Note
The Navien Zone Controller setting must be enabled when using the Ready-Link cable for
communication. Refer to “11.8 Setting the Space Heating Operation” on page 104 for details.