V10/V7.5/V5/V3.5 Installation and Operation Manual
Page
4-7
Section 4 Testing and Adjustment
Issue 3.5
4.3.5.6 Remote Selection of Fan Power
Supply (if applicable)
If the transmitter is configured for dual fan
power supply operation, verify fan power
supply (PS) A or B can be selected from a
remote location:
(a) Verify 4.3.5.1 is complete.
(b) Remotely select Fan PS B as the
active fan PS by activating an input to
the remote interface PWB's
Ext Fan
PS B
pin(s) [J4-31 (+)/ J4-32 (-)].
(c) The GUI will indicate fan PS B is
active. The remote interface PWB’s
Fan PS Status
output (J4-24) will be a
current-sink-to-ground.
(d) Remotely select fan PS A as the active
fan PS by activating an input to the
remote interface PWB's
Ext Fan PS A
pin(s) [J4-29 (+)/ J4-30(-)].
(e) The GUI will indicate that fan PS A is
active. The remote interface PWB’s
Fan PS Status
output (J4-24) will be an
open-collector.
4.3.5.7 Remote Preset Controls
Verify the six presets can be selected from
a remote location as follows:
(a) Verify 4.3.5.1 is complete.
NOTE
This procedure assumes that the preset
synchronization feature (see 3.6.12.7) is
enabled. This synchronizes the preset of
the associated M50 exciter (if used) with
the transmitter. The frequency and mode of
the M50 preset must match the transmitter
preset.
(b) Remotely select preset 2 by activating
an input to remote interface PWB's
Ext
Preset 2
pin(s) [J4-4 (+)/J4-5 (-)].
(c) The RF output, as displayed by the
RF
KILOWATTS
meter and GUI, will be
the preset 2 power level.
(d) The GUI will indicate that the
transmitter is operating in preset 2. The
remote interface PWB’s
Preset 2
Status
pin (J4-16) will be a current-
sink-to-ground.
(e) Remotely select preset 3 by activating
an input to remote interface PWB's
Ext
Preset 3
pin(s) [J4-6 (+)/J4-7 (-)].
(f) The RF output, as displayed by the
RF
KILOWATTS
meter and GUI, will be
the preset 3 power level.
(g) The GUI will indicate that the
transmitter is operating in preset 3. The
remote interface PWB’s
Preset 3
Status
pin (J4-17) will be a current-
sink-to-ground.
(h) Remotely select preset 4 by activating
an input to remote interface PWB's
Ext
Preset 4
pin(s) [J4-8 (+)/J4-9 (-)].
(i) The RF output, as displayed by the
RF
KILOWATTS
meter and GUI, will be
the preset 4 power level.
(j) The GUI will indicate that the
transmitter is operating in preset 4. The
remote interface PWB’s
Preset 4
Status
pin (J4-18) will be a current-
sink-to-ground.
(k) Remotely select preset 5 by activating
an input to remote interface PWB's
Ext
Preset 5
pin(s) [J4-10 (+)/J4-11 (-)].
(l) The RF output, as displayed by the
RF
KILOWATTS
meter and GUI, will be
the preset 5 level.
Содержание V10
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 52: ......
Страница 54: ......
Страница 55: ...Dimensions inches mm Dimensional Information V10 V7 5 Transmitter Issue 3 5 Not to Scale Figure 2 8 Page 2 29 ...
Страница 56: ......
Страница 57: ...Dimensions mm inches Dimensional Information V5 V3 5 Transmitter Issue 3 5 Not to Scale Figure 2 9 Page 2 30 ...
Страница 58: ......