V10/V7.5/V5/V3.5 Installation and Operation Manual
Page
3-25
Section 3 Operating Instructions
Issue 3.5
3.6.8 Select Metered Parameters
For monitoring and troubleshooting
convenience, you can change the main
screen to display any three of the following:
*
denotes used only in V10/V5
**
denotes used only in V10/V7.5
*** denotes used only in V7.5/V3.5
**** denotes used only in V7.5
***** denotes used only in V10
•
Forward
Power
•
Reflected
Power
•
PA
Voltage
•
Total PA Current
•
Reject Power (O/P or final output) **
•
Reject Power (A-C or A-D output)
•
Reject Power (E-G or E-H output) **
•
Reject Load Temperature (A-B)
•
Reject Load Temperature (B-C) ***
•
Reject Load Temperature (C-D) *
•
Reject Load Temperature (E-F) **
•
Reject Load Temperature (F-G) ****
•
Reject Load Temperature (G-H) *****
•
IPA Input Power (RF drive)
•
IPA
Forward
Power
•
IPA Reflected Power
•
IPA
PA
Voltage
•
Intake
Temperature
•
Exhaust
Temperature
•
Temperature
Rise
•
Controller
Temperature
•
Fan
Voltage
•
Combiner Top Fan Speed
•
Combiner Bottom Fan Speed
•
+2.5 V Reference Voltage
•
+5 V Power Supply Voltage
•
+15 V Power Supply Voltage
•
–15 V Power Supply Voltage
•
Efficiency (Dc to RF)
•
VSWR
(a) From the main menu, highlight
Meter
Presets
(using
f
and
g
) and press
Select
. A list of possible metered
parameters will be displayed (two at a
time, in the default display order of the
main screen).
(b) Press
Edit
to select the parameter to edit
and use
f
and
g
to scroll and select the
parameter to be monitored in its place.
The parameter order will follow the
default display order.
(c) Continue changing the main screen’s
displayed parameters by pressing
Edit
on the field to be changed. Press
Save
to
store the selection.
(d) Press
Back
to return to previous screen.
3.6.9 Set Real Time Clock
Default display
order
shown.
Meter names
not exactly as
indicated on
GUI
Main Menu
Software Version
Meter Presets
Real Time Clock
Ext Meter & Contrast
Ext Analog Samples
Select
Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Main Menu
Software Version
Meter Presets
Real Time Clock
Ext Meter & Contrast
Ext Analog Samples
Select
Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Real Time Clock
Time
Day
Date
11:39:59 Thu
25/May/2006
Edit
Back
11:26 98.10MHz 0.00kW 1 EXA IPAA/A FanA
Real Time Clock
Time
Day
Date
11:39:59 Thu
25/May/2006
Edit
Back
11:26 98.10MHz 0.00kW 1 EXA IPAA/A FanA
Meter Presets
Fwd Power
0 kW
0
6.00
Refld Power 0 W
0
600
Edit
Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Meter Presets
Fwd Power
0 kW
0
6.00
Refld Power 0 W
0
600
Edit
Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Main Menu
Power Control
Module Status
Events Log
Software Version
Meters Presets
Select
Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Main Menu
Power Control
Module Status
Events Log
Software Version
Meters Presets
Select
Back
11:26 98.10MHz 0.00kW 1 ExA IPAA/A FanA
Содержание V10
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 52: ......
Страница 54: ......
Страница 55: ...Dimensions inches mm Dimensional Information V10 V7 5 Transmitter Issue 3 5 Not to Scale Figure 2 8 Page 2 29 ...
Страница 56: ......
Страница 57: ...Dimensions mm inches Dimensional Information V5 V3 5 Transmitter Issue 3 5 Not to Scale Figure 2 9 Page 2 30 ...
Страница 58: ......