Page 5-24
V10/V7.5/V5/V3.5 Installation and Operation Manual
Issue 3.5
Section 5 System Level Troubleshooting
NOTE
In a V10/V7.5, an IPA changeover affects
both the IPA module and its associated IPA
PS (i.e., they are ganged together). In a
V5/V3.5, however, the IPA PA and IPA PS
have independent changeover functions.
•
IPA
fault (dual IPA V10/V7.5 only): An
IPA changeover can occur if the active
IPA [A (A19) or B (A20)] fails due to an
IPA related fault, such as
IPA Q3/Q4
Forward Low
alarm. See the
applicable paragraph under
IPA/PA
alarm (see 5.5.2) to troubleshoot.
•
IPA PA
fault (dual IPA PA V5/V3.5
only): An IPA PA changeover can
occur if the active IPA PA [A (A19A4)
or B (A19A3)] fails due to an IPA
related fault, such as
IPA Forward
Low
alarm. See the applicable
paragraph under
IPA/PA
alarm (see
5.5.2) to troubleshoot.
•
IPA PS
fault (dual IPA PS V5/V3.5
only): An IPA PS changeover can
occur if the active IPA PS [A (U1) or B
(U2)] fails due to an IPA PS related
fault, such as
PS Temp
alarm. See the
applicable paragraph under
Power
Supply
alarm (see 5.5.6) to
troubleshoot.
•
A
Fan PS
fault (dual fan PS
transmitters only): A fan PS
changeover can occur if the active fan
PS [A (U13) or B (U14)] fails due to a
related fault, such as
Fan PS Fail
alarm. See the applicable paragraph
under
Low Voltage Power Supply
alarm (see 5.5.4) to troubleshoot.
To reset the
Changeover
alarm and clear
the front panel alarm lamp (off):
•
In
the
Changeover
menu, toggle the
indicated
Main
module [A or B of
exciter, IPA (V10/V7.5), IPA PA (V5/
V3.5), IPA PS (V5/V3.5), or Fan PS] to
match the current
Active
module
indicated in the
Status
bar (A or B).
5.5.8 External Alarms
5.5.8.1 Interlock Open Alarm
An
Interlock Open
alarm occurs if the
transmitter interlock is open. Check the
interlock connection at remote interface
PWB (A44) TB1-1 and 2. If intact, check
all interlock switches. Otherwise, it may be
a problem with the interlock circuitry for
either the remote interface PWB or
control/display PWB.
5.5.8.2 Remote PWB Offline Alarm
A
Remote PWB Offline
alarm occurs if
the control/display PWB (A43) is not
receiving communications from the
remote interface PWB (A44). If the remote
interface PWB is receiving data updates
from the control/display PWB, the
Valid
Data Status
output (J4-26) on the remote
interface PWB is a current-sink-to-ground.
If the remote interface PWB is not
receiving communication from the control/
display PWB,
Valid Data Status
output
switches to an open collector. Check the
cabling between the control/display PWB
and the remote interface PWB. Check the
supply voltages applied to both PWBs.
5.5.9 EEPROM Alarms
If an
EEPROM Fail Cal
,
EEPROM Fail
Thresh
,
EEPROM Fail Meters
, or
EEPROM Fail Presets
alarm is displayed
on the GUI’s
Events Log
, enter the
associated GUI screen [Calibrate Meters
(see 3.6.12.3) for
EEPROM Fail Cal
,
Setup Thresholds (see 3.6.12.6) for
EEPROM Fail Thresh
, Meters Presets
(see 3.6.8) for
EEPROM Fail Meters
and
Presets (see 3.6.4) for
EEPROM Fail
Presets
) and press
Save
. Contact Nautel
if the problem persists.
5.6 FAN REMOVAL/REPLACEMENT
When a fan is found to be defective,
remove it and replace it with a functional
fan as follows:
5.6.1 RF Power Module Fan
If replacing an RF power module fan,
perform the following steps:
Содержание V10
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 52: ......
Страница 54: ......
Страница 55: ...Dimensions inches mm Dimensional Information V10 V7 5 Transmitter Issue 3 5 Not to Scale Figure 2 8 Page 2 29 ...
Страница 56: ......
Страница 57: ...Dimensions mm inches Dimensional Information V5 V3 5 Transmitter Issue 3 5 Not to Scale Figure 2 9 Page 2 30 ...
Страница 58: ......