V10/V7.5/V5/V3.5 Installation and Operation Manual
Page
5-35
Section 5 System Level Troubleshooting
Issue 3.5
(c) Disconnect all cables from the
applicable IPA splitter assembly:
A21 - A-D (V10/V5) or A-C (V7.5/V3.5):
Disconnect coaxial cables W11P1-
W14P1, W90P2 (if applicable) or
W87P2. Disconnect 8-pin MTA plug
P75 from A1J2.
A22 - E-H (V10) or E-G (V7.5):
Disconnect coaxial cables W15P1-
W18P1, W91P2 (if applicable) or
W86P2. Disconnect 8-pin MTA plug
P76 from A1J2.
(d) Remove and retain the hardware that
secures the assembly to the
transmitter cabinet (four M5 Phillips
head).
(e) Place the suspect IPA splitter
assembly on a suitable workbench for
troubleshooting/repair.
NOTE
If an operational IPA splitter assembly is
available, it may be installed in the
transmitter while the defective assembly is
being serviced.
For V10/V7.5 transmitters, if an operational
IPA splitter assembly is not available, the
defective IPA splitter assembly can be
removed for repair while the operational
IPA splitter assembly allows the transmitter
to operate at reduced power (foldback
threshold, see 5.5.3.2).
Refer to paragraph 5.14.2 to install an IPA
splitter assembly. Refer to the Repair
manual to troubleshoot or repair a
defective IPA splitter assembly.
5.14.2 IPA Splitter Assembly
Installation
Install an operational IPA splitter assembly
in the transmitter as follows:
(a) Reverse the order of steps in
paragraph 5.14.1.
NOTE
All coaxial cables and plugs have tags
near their connectors indicating their
designation and mating information. Use
these tags and the labels on the assembly
as an aid to reinstall the connectors and
coaxial cables removed in step 5.14.1 (c).
(b) Turn ac on at the service entrance and
restore the transmitter to operation.
5.15 PRINTED WIRING BOARD
(PWB) REPLACEMENT
Replace defective printed wiring boards
(PWB) and perform necessary adjustments
as follows:
NOTE
If a replacement PWB has been provided
by the factory, it was pre-tested and should
not require any adjustment.
(a) Press the
Control - RF Off
switch.
Turn off ac power at the ac service
entrance.
(b) Remove any PWB covers or
impediments and disconnect all mating
plugs from the defective PWB.
Remove all mounting hardware.
(c) Install the replacement PWB using the
hardware removed in step (b).
Reconnect the mating connector plugs
with their respective connectors on the
PWB.
(d) Turn on ac power at the ac service
entrance.
NOTE
Proceed to the applicable paragraph
5.15.1 - 5.15.4 for additional PWB setup
information. If it is necessary to
troubleshoot a PWB, refer to the Repair
Manual for further information.
Содержание V10
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 52: ......
Страница 54: ......
Страница 55: ...Dimensions inches mm Dimensional Information V10 V7 5 Transmitter Issue 3 5 Not to Scale Figure 2 8 Page 2 29 ...
Страница 56: ......
Страница 57: ...Dimensions mm inches Dimensional Information V5 V3 5 Transmitter Issue 3 5 Not to Scale Figure 2 9 Page 2 30 ...
Страница 58: ......