![Nautel V10 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/nautel/v10/v10_users-installation-and-operation-manual_711222036.webp)
Page 2-12
V10/V7.5/V5/V3.5 Installation and Operation Manual
Issue 3.5
Section 2 Preparation for Use and Installation
2.2.15.1 RF Monitor Samples
A true sample of the RF output voltage is
provided on the RF power probe
assembly’s (A42)
RF MONITOR
BNC
connector (J3) at the output of the
transmitter. This
output should be applied
to a modulation monitor with 50
Ω
input
impedance. It may also be monitored by
an oscilloscope during maintenance
procedures. Nominal levels (for rated
power) are as follows:
Transmitter, Mode, Power
RF Monitor
V10, FM, 10,000 W
2.5 V
V10, FM+HD, 7,300 W
2.2 V
V10, HD, 2,800 W
2.2 V
V7.5, FM, 7,500 W
2.2 V
V7.5, FM+HD, 5,480 W
1.9 V
V7.5, HD, 2,100 W
1.9 V
V5, FM, 5,000 W
1.7 V
V5, FM+HD, 3,650 W
1.6 V
V5, HD, 1,400 W
1.6 V
V3.5, FM, 3,750 W
1.5 V
V3.5, FM+HD, 2,740 W
1.4 V
V3.5, HD, 1,050 W
1.4 V
True samples of the IPA amplifier(s)
output voltage are provided on the IPA
splitter’s (A21 and A22, if applicable)
IPA
RF MONITOR
BNC connector (J3) at the
rear of the transmitter. These
outputs
should be applied to a modulation monitor
with 50
Ω
input impedance. Nominal
levels (based on required IPA power) are
as follows:
Transmitter, Mode, Power
IPA
Monitor
V10, FM, 10,000 W (250 W IPA)
1.0 V
V10, FM+HD, 7,300 W
0.4 V
V10, HD, 2,800 W
0.4 V
V7.5, FM, 7,500 W (250 W IPA)
1.0 V
V7.5, FM+HD, 5,480 W
0.4 V
V7.5, HD, 2,100 W
0.4 V
V5, FM, 5,000 W (250 W IPA)
1.0 V
V5, FM+HD, 3,650 W
0.2 V
V5, HD, 1,400 W
0.3 V
V3.5, FM, 3,750 W (250 W IPA)
1.0 V
V3.5, FM+HD, 2,740 W
0.2 V
V3.5, HD, 1,050 W
0.3 V
Table 2-4:
Remote Monitor Connections
(TB1, J4 or J6 of remote interface PWB)
Remote Alarm, Status
or Sample
Terminal or Pin
Summary Alarm
TB1-4
Interlock Open Alarm
TB1-5
Low Battery/Memory Fail
TB1-6
Low RF Alarm
TB1-7
Changeover Alarm
TB1-8
PA Fail Alarm
TB1-9
High Reflected Power Alarm
TB1-10
High Temperature Alarm
TB1-11
Transmitter Ready
TB1-13
RF On Status
TB1-14
Exciter Status
TB1-15
IPA Status
TB1-16
+15 V dc supply
TB1-18
Forward Power Sample
TB1-20
Reflected Power Sample
TB1-21
Ground TB1-3,12,17,19
Preset 1 Status
J4-15
Preset 2 Status
J4-16
Preset 3 Status
J4-17
Preset 4 Status
J4-18
Preset 5 Status
J4-19
Preset 6 Status
J4-20
Remote Status
J4-22
IPA Power Supply Status
J4-23
Fan Supply Status
J4-24
Valid Data Status
J4-26
Ground J4-1,14,21,33,34,35
Ac Fault Alarm
J6-1
Power Supply Fail Alarm
J6-2
IPA/RF Fail Alarm
J6-3
PA Voltage Sample
J6-9
Exciter Forward Pwr Sample
J6-10
Intake Air Temp Sample
J6-11
Exhaust Air Temp Sample
J6-12
Total PA Current Sample
J6-21
Ground J6-7,8,13,14,20,33
Содержание V10
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 52: ......
Страница 54: ......
Страница 55: ...Dimensions inches mm Dimensional Information V10 V7 5 Transmitter Issue 3 5 Not to Scale Figure 2 8 Page 2 29 ...
Страница 56: ......
Страница 57: ...Dimensions mm inches Dimensional Information V5 V3 5 Transmitter Issue 3 5 Not to Scale Figure 2 9 Page 2 30 ...
Страница 58: ......